Rs485 connection
Table of Contents

Advertisement

Available languages

Available languages

Installation instructions, only for experts
Function
CMD Parameter
Heater tem-
get
perature
Bench tem-
get
perature
Actual
get
humidity
Foil tem-
get
perature
Heating
set
time limit
get
get
User pro-
set
grams
set
get
get
Commands (CMD)
Status
temp-heater
val
temp-bench
val
humidity
val
foil-temp
val
heattimer
val
heattimer
heattimer
val
user-prog
on/off
user-prog
val
user-prog
user-prog
val
Description
Value
Queries the temperature meas-
ured by the heater sensor
Queries the temperature meas-
ured by the bench sensor
Queries the humidity meas-
ured by the humidity sensor
Queries the temperature
measured by the foil sensor
0-1440
Sets a selected value between
0 and 1440 minutes* for the
heating time
Queries the status of the heat
timer (on/off)
Queries the remaining heat-
ing time in minutes
Starts/stops the selected user
program
1-5
Selects a user program
Queries the status of the user
program function
Queries the number of the user
program currently operating
p. 8/12