7.
Decommissioning
7.1
Temporary shutdown
In the event of lengthy periods of non-use:
¶
Disconnect KTS 200 from the mains.
7.2
Change of location
¶
If the KTS 200 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
¶
The KTS 200 is only ever to be transported in the
original or equivalent packaging.
¶
Unplug the electrical connection.
¶
Heed the notes on initial commissioning.
KTS 200, accessories and packaging should
be sorted for environmental-friendly recycling.
¶
Do not dispose KTS 200 into household
waste.
Only for EC countries:
The KTS 200 is subject to the European di-
rective 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶
Proper disposal of KTS 200 prevents en-
vironmental pollution and possible health
hazards.
Robert Bosch GmbH
Decommissioning | KTS 200 | 13
8.
Technical Data
8.1
General data
Property
Operating voltage
Power consumption
TFT display
Dimensions (L x W x H)
Weight (without accessories)
Operating temperature
Storage temperature
Relative humidity
Degree of protection
8.2
Interface protocols
The following interfaces and their associated protocols
are supported for control unit diagnosis in compliance
with ISO 15031:
R
ISO 9141-2 (communication lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(communication lines CAN-H and CAN-L)
R
CAN Single Wire
R
CAN Low Speed
8.3
Power supply unit
Property
Input voltage
Input frequency
Output voltage
Operating temperature
Storage temperature
en
Value/range
8 VDC — 28 VDC
approx. 7 watts
3.5"
320 * 240 Pixel
140*220*40 mm
600 g
5 °C – 40 °C
41 °F – 105 °F
-25 °C – 60 °C
-13 °F – 140 °F
90 % (at 25 °C)
IP 30
Value/range
100 VAC — 240 VAC
47 Hz — 63 Hz
15 V
5 °C – 40 °C
41 °F – 105 °F
-25 °C – 60 °C
-13 °F – 140 °F
|
1 689 989 288