5. Data Report

The device will immediately send a version packet report along with two uplink packets including temperature, battery voltage,
acceleration and velocity of the X, Y, and Z axes.
The interval between these two packets will be 10 seconds.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Max Interval = 60 min = 3600s
BatteryChange = 0x01 (0.1v)
AccelerationChange = 0x0003
ActiveThreshold = 0x0003
InActiveThreshold = 0x0002
Three-axis acceleration and velocity:
While the data of three-axis accelerometer of the device is lower than InActiveThreshold and the duration has to be lesser than
5 seconds, at this time, if the vibration continues (the data of three-axis accelerometer is higher than InActiveThreshold ), it will
be delayed for 5 seconds. Until the data of three-axis accelerometer is lower than InActiveThreshold, and the duration is more
than 5 seconds, R718E would send two packet, one is the data of three-axis accelerometer, and the other would be sent after 10
seconds with the data of the speed of three-axis & the temperature.
Note:
(1) The device report interval will be programmed based on the default firmware which may vary.
(2) The interval between two reports must be the minimum time.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Any number between
1~65535
to resolve uplink data.
Max Interval
(Unit:second)
Any number between
1~65535
Reportable Change
Can not be 0.
6
Current Change≥
Reportable Change
Report
per Min Interval
Current Change<
Reportable Change
Report
per Max Interval