Page 1
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Table of Content 1. Introduction ................................3 2. Appearance ................................3 3. Main Features ................................4 4. Application ................................4 5. Set up Instruction ..............................5 6. Data Report ................................6 6.1 ActiveThreshold and InActiveThreshold ......................7 6.2 Calibration ................................ 7 6.3 Example of data configuration ........................
R718EB is the Class A device based on the LoRaWAN protocol of Netvox. The device detects the tilt angle of three axes. When the device moves or shakes beyond the set threshold, and the angle variation of any one of the three axes is greater than the set threshold, it will immediately report the current tilt angle of the X, Y, and Z axes and the battery voltage.
⚫ Low power consumption and long battery life Battery Life: ⁻ Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html ⁻ At this website, users can find battery life time for variety models at different configurations. 1. Actual range may vary depending on environment.
5. Set up Instruction On/Off Power on Insert batteries. (users may need a screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off Press and hold the function key for 5 second, and the green indicator flashes 20 times. (Restore to factory setting) Power off Remove Batteries.
(1) The device report interval will be programmed based on the default firmware which may vary. (2) The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index...
The 0g offset is an important accelerometer indicator because it defines the baseline used to measure acceleration. After installing R718EB, users need to let the device rest for 1 minute, and then power on. Then, turn on the device and wait for the device taking 1 minute to join the network.
(3) Assuming that the Active Threshold is set to 10m/s2, the value to be set is 10/9.8/0.0625=16.32,and the last value obtained is an integer and is configured as 16. Configure device parameters ActiveThreshold=16, InActiveTime=5 Downlink: 03C8001005000000000000 0010(H = 16(D Device returns: 83C8000000000000000000 (configuration is successful) 83C8010000000000000000 (configuration failed) Read device parameters...
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Users push the button, Wakes up and collects data REPORTS 3.5V. 3.5V |3.5-3.6|=0.1 Wakes up and Recalculate MaxTime. REPORTS 3.5V collects data 3.5V Does not report sleeping sleeping 1H 10...
8. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
9. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.