This section provides the following power specifications for the switch:
AC power specifications
Typical power consumption
PoE+ specifications
The following table describes the AC power specifications.
Table 3: AC power specifications
Model
ERS 4950GTS
ERS 4926GTS
June 2016
Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series (NN47212-302,
on page 4
on page 5
on page 6
Number of
Power supply
Power
supplies
Rated
1
250 W
2
250 W/PSU
1
250 W
2
250 W/PSU
1
250 W
2
250 W/PSU
0 to 95 percent non-condensing
0 to 95 percent non-condensing
3,048 m (10,000 feet) above sea level
0 to 12,192 m (0 to 40,000 feet) above sea level
At 25°C Ambient Temperature, less than 48 dBA
typical, at 50°C, less than 61 dBA.
• No nearby heat sources such as hot air vents or
direct sunlight
• No nearby sources of severe electromagnetic
noise
• No excessive dust
• Adequate power source within six feet; one circuit
required for each power supply (see table, AC
power specifications)
• At least 2 inches (5.08 cm) on each side of the
switch unit for ventilation
• Cables should be dressed to prevent blocking air
flow.
Input power
(margined by 10%)
Line voltage
Watts
(Total)
200–240 VAC
53.14
200–240 VAC
58.88
100–110 VAC
53.67
100–110 VAC
59.53
200–240 VAC
39.37
200–240 VAC
46.23
ver 02.01)
Thermal
rating
(BTUs/hr
maximum)
Amps
0.30
181.31
0.44
200.89
0.51
183.12
0.58
203.11
0.25
134.33
0.40
157.73
Table continues...