Exmark Z Turf Equipment Z-SPRAY Operator's Manual page 42

Table of Contents

Advertisement

Operation
Note: This measurement is the effective
spreading width.
Calculating the Application Rate
1.
Determine the amount of product to be applied.
2.
Determine the calibration course
A.
Determine the amount of product to be spread
2
per 1,000 ft
(93 m
rate from the Spreading Charts section or
the product manufacturer's label as a guide.
B.
Determine a course length by dividing 1,000
2
2
ft
(93 m
) by the effective spread width.
For example, if the effective width is 6 feet
(1.8 meters), then the calibration course length
equals 167 ft (51 m).
Course Length
2
1,000 ft
(93 m
6 ft (1.8 m)
C.
The calibration course is 6 ft (1.8 m) by 167
ft (51 m).
D.
Measure and visibly mark the course length.
Make sure to allow ample distance before the
starting marker to ensure the spreader is at
full speed when crossing the first mark of the
course.
3.
Set the appropriate gate dial setting (reference the
Spreading Charts section as a starting point).
4.
Add material to the hopper (for example, 25 lb
(11.3 kg) was added).
5.
Drive the spreader over the calibration course
while applying the material.
6.
Empty the remaining material of the hopper into
a clean bucket.
7.
Weigh the bucket containing the material and
record the weight. Pour the contents back into
the hopper and then weigh the empty bucket.
Subtract these two amounts to determine the
amount of material remaining in the hopper (for
example, 20 pounds (9 kg) remains.)
8.
Subtract the amount remaining in the hopper
(step 7) from the amount originally added (step
4); the result is the amount applied to the course.
Amount Applied
25 lb (11.3 kg) – 20 lb (9 kg) = 5 lb (2.3 kg)
2
). Use the recommended
2
)
= 167 ft (51 m)
For this example, 5 lb (2.3 kg) was applied to
2
2
1,000 ft
(93 m
).
9.
If necessary, adjust the rate dial to achieve the
recommended amount to be applied and repeat
the procedure. Once the correct application rate
is achieved, repeat this procedure an additional
time to verify the results.
Note: Designate a new calibration course each
time, so the turf is not damaged.
Spreader Pattern Adjustment
If the spread pattern is skewed or dispensing too
light/heavy to one side (see Figure 30 and Figure 31),
adjust the gate as follows:
1. Heavy to left side
2. Move ramp pattern to
shaded position
Note: Do Not adjust the ramps to split product flow.
Use only the front or rear ramp positions as shown.
1.
Unlock the spreader pattern control by turning
the handle counterclockwise 90 degrees (see
Figure 31).
To adjust when the material pattern is heavy:
• to the left side, slightly pull the handle up.
• to the right side, slightly push the handle
down.
42
Figure 30
3. Heavy to right side
g025543