Calorex Pro-Pac Series Owners & Installation Manual page 35

Hide thumbs Also See for Pro-Pac Series:
Table of Contents

Advertisement

Available languages

Available languages

AIR TO WATER HEAT PUMPS FOR SWIMMING POOL AND HOT WATER APPLICATIONS.
400V 3N~ 50HZ UNITS (BMY)
DUTY
Air On @ 20°C, 65%RH
Output To Water (@ 26ºC)
Electrical Input
Air On @ 10°C, 80%RH
Output To Water (@ 26ºC)
Electrical Input
Air On @ 0ºC, 99%RH
Output To Water (@ 26ºC)
Electrical Input
ELECTRICAL DATA
Electrical Supply 3 Phase
Minimum Supply Capacity 3 Phase
Recommended Supply Fuse 3 Phase
Max Starting Current STD (LRA)
Max Starting Current S/Start (LRA)
AIR DATA
Nominal Air Flow
Fan External Resistance
Fan External Resistance
WATER DATA PPT Pro-PacS
Water Flow ±10%
Pressure Drop (Water)
Water Connections
Condensate Water Connections
WATER DATA PP Pro-PacS
Water Flow ±10%
Pressure Drop (Water)
Water Connections
GENERAL DATA
Hermetic System
Gas Charge (R407c) PPT Pro-PacS
Carbon dioxide equivalent
Gas Charge (R407c) PP Pro-PacS
Carbon dioxide equivalent
Compressor Type
Fan Type
*Sound Pressure Level @3m AIR ON
*Sound Pressure Level @3m AIR OFF
*Sound Pressure Level @3m SIDE
DIMENSION DATA
Width (unpacked) PPT Pro-Pac
Width (unpacked) PP Pro-Pac
Depth (unpacked)
Height (unpacked)
Weight (unpacked) PPT Pro-Pac
Weight (unpacked) PP Pro-Pac
Width (export, packed)
Depth (export, packed)
Height (export, packed)
Weight (export, packed) PPT Pro-Pac
Weight (export, packed) PP Pro-Pac
NOTES
(1) Weight and Dimensions Nett.
(2) Allow 500mm clearance to service panels.
(3) Minimum air temperature 7°C.
(4) Water to have correct balance pH 7.2 -7.8. Free Chlorine 1.0-2.0 ppm Domestic, 3.0-6.0 Commercial.
(5) Dantherm Ltd. reserve the right to change or modify models without prior notice.
(6) R407c Global Warming Potential (GWP) 1774.
*(7) Noise tests performed in accordance with BS ISO 3744:2010: k factor 0.
SD566252 ISSUE 51
model
Pro-Pac 30
Pro-Pac 45
UNITS
HEATING
kW
32
kW
7.8
kW
25.5
kW
7.3
kW
19.2
kW
5.98
V/ph/Hz
|--------------- ---------------- 400V 3N~/50Hz ----------------- ---------------|
A
20
A
30
A
80
A
31
m3/hr
5500
mm WG
0
mm WG
N/A
L/min
250
m hd
0.7
inches
2" UNION SKT 2" UNION SKT
inches
1½" BSPM
1½" BSPM
L/min
66
m hd
2.1
inches
1½" BSPM
1½" BSPM
kg
13
tonnes
23.1
kg
11.5
tonnes
20.4
SCROLL
AXIAL
dB(A)
64
dB(A)
60
dB(A)
61
mm
1585
mm
1555
mm
790
mm
1080
kg
233
kg
TBA
mm
1775
mm
900
mm
1250
kg
254
kg
TBA
Pro-Pac 70
40
62
9.75
14.4
32
50
8
12.5
23.8
36
7.67
10.96
22
35
30
50
96
174
33
40
12000
14000
0
0
4.5
6
300
500
0.4
1.5
3" BSPM
1½" BSPM
1½" BSPM x 2
66
133
4.2
3.9
1½" BSPM
16.8
17.2
29.8
30.5
16
16.4
28.4
29.1
SCROLL
SCROLL
AXIAL
AXIAL
65
70
61
64
64
65
1695
1840
1665
1810
1060
1190
1330
1310
337
435
346
472
1875
2020
1170
1300
1500
1480
446
562
463
588
Pro-Pac 90
Pro-Pac 140
80
124
19.5
29
64
100
16
25
50.1
71.9
16.17
21.93
43
67
60
100
96
174
33
40
24000
28000
0
0
4.5
6
600
1000
1.4
2.1
3" BSPM
4" BSPM
1½" BSPM x 2
133
266
4.2
5.3
1½" BSPM
2" BSPM
17 X 2
15 X 2
30.2 x 2
26.6 x 2
16 x 2
15 X 2
28.4 x 2
26.6 x 2
2 x SCROLL
2 x SCROLL
2 x AXIAL
2 x AXIAL
65
70
64
67
61
65
2095
2250
2065
2210
1190
1650
1350
1340
628
508
TBA
872
2295
2470
1310
1770
1520
1505
776
728
TBA
1092
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents