Calorex Pro-Pac Series Owners & Installation Manual page 14

Hide thumbs Also See for Pro-Pac Series:
Table of Contents

Advertisement

Available languages

Available languages

PR0-PAC SYSTEM OWNER INSTALLATION MANUAL
RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP WITH SINGLE
SINGLE PHASE
SUPPLY TO SUIT
CAPACITY OF WATER
PUMP
L
N
L
N
N
L
N
RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP
THREE PHASE
SUPPLY TO SUIT
CAPACITY OF
WATER PUMP
L3
L2
L1
L
L3
L2
L1
4 POLE N/O STARTER WITH
OVERLOAD AND 230v 50Hz COIL
RATED TO SUIT WATER PUMP
N
L1
L2
WATER PUMP
THREE PHASE
L3
14
MAINS SUPPLY IN
PHASE WATER PUMP
SWITCHED FUSE ISOLATOR
WITHIN 2m OF HEAT PUMP AND
SIZED IN ACCORDANCE WITH
L
4 POLE N/O STARTER WITH
OVERLOAD AND 230V 50Hz COIL
RATED TO SUIT WATER PUMP
N
L
WATER PUMP MORE THAN
¾ HP SINGLE PHASE
Fig. 6
WITH THREE PHASE WATER PUMP
SWITCHED FUSE ISOLATOR WITHIN
2m OF HEAT PUMP AND SIZED IN
ACCORDANCE WITH DATA SHEET
Fig. 5
DATASHEET
1
CALOREX HEAT PUMP
THREE PHASE
2
4
5
6
8
10
11
3
7
9
N
L1 L2 L3
CALOREX
HEAT PUMP
THREE PHASE
1
2
3
4
5
6
7
8
9
N
L1
L2
L3
SD566252 ISSUE 51
10
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents