Calorex Pro-Pac Series Owners & Installation Manual page 26

Hide thumbs Also See for Pro-Pac Series:
Table of Contents

Advertisement

Available languages

Available languages

PR0-PAC SYSTEM OWNER INSTALLATION MANUAL
Pro-Pac 140BMY THREE PHASE (400V 3 N~ 50Hz)
SMART CLOCK
FEED TERMINALS
(N) 8
9 (L)
RELAY (R2)
B
A
A2
A1
DELAY TIMER (4)
(30 SECS)
FAN 1
CONTACTOR
COMP 1 CONTACTOR
A2
A1
(N/O) 64
FAN 2 CONTACTOR
COMP 2 CONTACTOR
A2
A1
(N/O) 64
DEFROST
LIGHT
FRIDGE CCT 1 REVERSING VALVE
FRIDGE CCT 2 REVERSING VALVE
DELAY TIMER (6)
(3 SECS)
A2
A1
RELAY (R4)
(N/O) 18
B
A
15 (COM)
(N/C) 16
COMP 1 MCB AUX BLOCK
COMPRESSOR 1
TRIP / OFF = BREAK CONTACT
CONTACTOR
A2
A1
COMP 2 MCB AUX BLOCK
COMPRESSOR 2
TRIP / OFF = BREAK CONTACT
CONTACTOR
A2
A1
FRIDGE CCT 1 VALVE COIL
(LIQUID LINE SHUT OFF)
COMPRESSOR 1 HEATER
COMP
1
FRIDGE CCT 2 VALVE COIL
(LIQUID LINE SHUT OFF)
COMPRESSOR 2 HEATER
COMP
2
26
(N) 2
1 (L)
(N/O) 4
6 (COM)
(N/C) 5
MCB SETTINGS
CONTROL
COMPRESSORS
FANS
2.5A
36.8A
63 (AUX)
(N/O) 6
9 (COM)
63 (AUX)
(N/C) 3
(N/O) 4
7 (COM)
(N/C) 1
2
(N)
3 (N/O)
1 (COM)
(COM) 8
5 (N/O)
4 (N/C)
2 (N/C)
B
A
(N/O) 18
15 (COM)
RELAY (R3)
(N/C) 16
A2
A1
DELAY TIMER (5)
(3 SECS)
18 (N/O)
15 (COM)
(COM) 9
6 (N/O)
16 (N/C)
3 (N/C)
A2
A1
DELAY TIMER (2)
(6 MINS)
18 (N/O)
15 (COM)
(COM) 7
4 (N/O)
16 (N/C)
1 (N/C)
A2
A1
DELAY TIMER (3)
(7 MINS)
B
A
RELAY (R1)
FAN
1
FAN
2
(N/O) 14
13 (AUX)
(N/C) 22
21 (AUX)
L1
(N/O) 2
1
L2
(N/O) 4
3
L3
(N/O) 6
5
COMPRESSOR 1 CONTACTOR
13
(N/O) 14
(AUX)
(N/C) 22
21 (AUX)
L1
(N/O) 2
1
L2
(N/O) 4
3
L3
(N/O) 6
5
COMPRESSOR 2 CONTACTOR
PHASE ROTATION
RELAY
L1
L2
(COM) 11
(N/O) 14
L3
INTERLOCK
TERMINALS
(N/O) 4
7 (COM)
(N/C) 1
B
A
RELAY (R5)
2.7A
(N/O) 6
9 (COM)
(N/C) 3
(N/O) 4
7 (COM)
(N/C) 1
(N/O) 54
3 (N/O)
1 (COM)
(COM) 8
5 (N/O)
(N/O) 54
4 (N/C)
2 (N/C)
2 (N)
18 (N/O)
15 (COM)
16 (N/C)
A2
A1
DELAY TIMER (1)
(12 HRS)
(N/O) 2
1
(N/C) 2
(N/O) 4
3
(N/C) 4
(N/O) 6
5
(N/C) 6
FAN 1 CONTACTOR
FAN 1 CIRCUIT BREAKER
TRIP / OFF = BREAK CONTACT
(N/O) 2
1
(N/C) 2
(N/O) 4
3
(N/C) 4
(N/O) 6
5
(N/C) 6
FAN 2 CONTACTOR
FAN 2 CIRCUIT BREAKER
TRIP / OFF = BREAK CONTACT
(N/C) 2
(N/C) 4
(N/C) 6
COMPRESSOR 1 CIRCUIT BREAKER
TRIP / OFF = BREAK CONTACT
(N/C) 2
(N/C) 4
(N/C) 6
COMPRESSOR 2 CIRCUIT BREAKER
TRIP / OFF = BREAK CONTACT
CONTROL CIRCUIT BREAKER
TRIP / OFF = BREAK CONTACT
(N/C) 2
1
(N/C) 4
3
(N/C) 6
5
FAULT LIGHT
COMP 2
CONTACTOR
53 (AUX)
COMP 1
CONTACTOR
53 (AUX)
FAULT LIGHT
FRIDGE CCT 1
FAULT LIGHT
FRIDGE CCT 2
1
3
5
1
3
5
1
3
5
1
3
5
SD566252 ISSUE 51