Chapter 3 Deployment
Parameter data
IM 353-1DP01
DP-V0
3-12
Note
Please note to place the following modules during hardware configuration
to the first three slots:
These modules are automatically placed using the Siemens SIMATIC
Manager:
At usage of the IM 353-1DP01 (DP-V0) you have the following parameter
data:
Byte
Bit 7 ... Bit 0
0
Bit 2 ... 0: 0 (fix)
Bit 3: 0 = WD-Timebase 10ms
1 = WD-Timebase 1ms
Bit 4: 0 (fix)
Bit 5: 0 = Publisher-Mode not available
1 = Publisher-Mode available
1
00h (fix)
2
08h (fix)
3
0Ah (fix)
4
81h (fix)
5
00h (fix)
6
00h (fix)
7
Bit 0: 0 = Identifier-related diagnostic enable
1 = Identifier-related diagnostic disable
Bit 1: 0 = Module status enable
1 = Module status disable
Bit 2: 0 = Channel-related diagnostic enable
1 = Channel-related diagnostic disable
Bit 3: 0 (fix)
bit 4: 0 (fix)
Bit 5: 0 = V0: Diagnostic interrupt not available
1 = V0: Diagnostic interrupt available
Bit 6: 0 = V0: Hardware interrupt not available
1 = V0: Hardware interrupt available
Bit 7: 0 (fix)
8
Bit 7 ... 0: 0 (fix)
9 ... 12 00h (fix)
1)
Using the Siemens SIMATIC Manager this value is automatically set and can not be
changed.
Manual VIPA System 300S
Config for Slot1
Config for Slot2
Config for Slot3
HB140E - IM - RE_353-1DP01 - Rev. 14/47
Default
1)
00h
00h
08h
0Ah
81h
00h
00h
70h
00h
00h