  • Page 1 FIREBOX DECO ® FIREBOX LUCE PLUS ® FIREBOX RIGA WOOD INSERTS ® UK Installation, use and maintenance page 2...
  • Page 2: Table Of Contents

    Unpacking Installation Introduction about use Maintenance Troubleshooting The undersigned company, EDILKAMIN S.p.A., with registered office in Via Vincenzo Monti 47 - 20123 Milan (Italy) - Italian Tax ID code and VAT number 00192220192 Hereby declares, under its sole responsibility, that:...
  • Page 3: Introduction

    • the warranty certificate accompanying the product If you lose it, you can request a copy or download it • the purchase receipt given to you by the retailer from www.edilkamin.com • the declaration of conformity given to you by the installer.
  • Page 4: Safety Information

    DO NOT PLACE LAUNDRY ON neither Edilkamin nor the retailer are liable for THE APPLIANCE. DO NOT PLACE DRYING damage resulting from incorrect installation or RACKS WITHIN THE SAFETY CLEARANCE.
  • Page 5: Technical Data

    VERSION V Power absorbed in stand by The above data is for guidance only and was measured during certification by a notified body. EDILKAMIN s.p.a. reserves the right to modify the product without notification in the inte- rests of improvement.
  • Page 6: Dimensions

    DIMENSIONS Dimensions in cm FIREBOX DECO FIREBOX LUCE PLUS FIREBOX LUCE PLUS Mod. 54 Mod. 62 Glass dimensions 52x27,5 h cm Glass dimensions 64,5x49 h cm Glass dimensions 68,5x55,5 h cm Ø 14 Ø 20 Ø 20 Ø 20 ducted air...
  • Page 7: Unpacking

    UNPACKING PREPARATION AND UNPACKING DETACH THE PRODUCT FROM THE PALLET The packaging materials are neither toxic nor noxious Remove the product from the pallet while being and do not require special disposal. careful to protect the door and its glass panel from The user is responsible for storing, disposing of and mechanical impacts which could damage them.
  • Page 8 UNPACKING PACKAGING The packaging can provide a useful indication of the product’s condition. Check the packaging on receipt and report any anomalies to the reseller straight away. The packaging comprises a single box containing the firebox and the following items: Description figure No.
  • Page 9: Installation

    INSTALLATION PRODUCT HEIGHT FIXATION Be fixed on a support stand option or in a specific Use the screws to fix the product. self-made one. Failure to follow the above instructions can cause the insert to tip over with possible serious injury to the user. NOTE SUPPORT STAND OPTION As far as the EXTERNAL AIR INLET DEVICE is...
  • Page 10 INSTALLATION REMARKS ON INSTALLATION Checking the suitability of the installation Note that: space • The appliance may only be installed by a qualified • The room must have a volume of at least 40 m technician authorised to issue the declaration of •...
  • Page 11 INSTALLATION FLUE SYSTEM Electricity lines There must be no electricity lines in the (Fumes duct, flue and chimney pot) walls or ceiling of the fi replace installation This chapter has been drawn up pursuant to European area. regulations EN 13384, EN 1443, EN 1856 and EN 1457.
  • Page 12 INSTALLATION THE SMOKE CHANNEL EXTERNAL AIR INTAKE (Figs. A-B) • if in metal must have a CE marking (EN 1856-2) or The connection with the outside, made with a cross- similar national law; sectional area of at least 80/200 cm² (depending on •...
  • Page 13 16 cm flue or the fi tting for a Ø 20 cm flue (Fig. C) If the covering is produced by EdilKamin, you will fi f) wrap the section of steel pipe with a multilayered nd instructions for correctly positioning Firebox®...
  • Page 14 INSTALLATION HOT-AIR CIRCULATION AND DUCTING The product is supplied with two anti-corrosion (FIG. D) discs (one on the outside and one on the inside of the The air drawn from the outside through the special combustion chamber). mechanism (A) is mixed with air drawn from the room They must be removed during unpacking and disposed through the lower grilles (B).
  • Page 15 INSTALLATION INSTALLATION OF HOT-AIR CIRCULATION KITS There are three kits for ducting hot air that include everything necessary for the following three cases: KIT UNO (fig. D - E) only the fireplace room - remove the two pre-cut plugs from the Firebox® cover by pressing inwards;...
  • Page 16 INSTALLATION Facings, gather hood and vents Face the product only after having completed the following steps: • connection of the product to the smoke outlet and air intake; • inspection of the product when hot; • check to verify whether the product is levelled. The installer must implement all the installation good practices and take all the necessary precautions against overheating and fire.
  • Page 17 VENTILATION FORCED DESCRIPTION Parameter Value Unit of The ventilation regulator for wood inserts allows speed measurement selection of the heated air (convection) emitted from Power supply 230 +/- 15% the fireplace into the environment. Frequency 50/60 INSTALLATION Power the “Control Unit” upstream with a Only a qualified technician is authorised to carry out differential circuit breaker in accordance the installation.
  • Page 18: Introduction About Use

    USER INSTRUCTIONS SMOKE DAMPER ADJUSTMENT: in the event of diffi culty clearing the smoke (low draught), evacuation can be improved by adjusting the screw on the damper control rod. By turning the screw (clockwise) and closing the door, the damper will remain slightly inclined, helping the smoke to fl ow out.
  • Page 19 When should wood be added? When the fuel is • possible irreversible changes to the colour of the almost completely consumed to embers. With the paint on the metal parts for which Edilkamin or the glove supplied, slowly open (to avoid formation of retailer cannot be held liable.
  • Page 20 USER INSTRUCTIONS FORCED VENTILATION (FIG. H) This is achieved with the use of two fans (17) inserted in the lower part of Firebox®, a temperature thermostat housed next to one of the two fans and a two-speed switch (18) to be placed near the fi replace. Operation of the two-speed switch: - to start the fans, set the switch to “manual”...
  • Page 21: Maintenance

    MAINTENANCE Cleaning the glass Cleaning the external parts The covering must be clean without using aggressive You can use specififi c products to clean the glass (see detergents. Do not wet with cold water when the our Glasskamin pricelist). covering is hot because the thermal shock could Do not spray the product on painted parts or the cause damage.
  • Page 22 We recommend emptying out the pellet tank. SPARE PARTS For any spare parts, contact your reseller or technician. Using non-original spare parts may damage the appliance and relieves Edilkamin of all liability for damage resulting therefrom. Every not allowed modification is forbidden...
  • Page 23: Troubleshooting

    TROUBLESHOOTING If problems occur, the product shuts itself off automatically. Problems Action In case of smoke leaking from the Check if: fireplace hearth • Installation is correct (smoke channel, chimney flue, stack, air intake); • The wood used is dry; •...
  • Page 24 *941984-GB* w w w . e d i l k a m i n . c o m cod. 941984-GB 12.19/C...