Specifications

This ice maker is designed to be installed indoors,
in a controlled environment. Although it can operate
in a wide range of air and water temperatures, it
will provide the best performance if not subject to
extremes.
Air Temperature Limitations
o
Maximum: 100
F or 38
o
Minimum: 50
F or 10
Water Temperature Limitations
o
Maximum: 100
F or 38
o
Minimum: 40
F or 4.4
Water Pressure, Potable
Maximum: 80 PSI or 5.5 BAR
Minimum: 20 PSI or 1.3 BAR
Water Pressure, Condenser inlet
Maximum: 145 PSI or 10 BAR
Minimum: 20 PSI or 1.3 BAR; can be as low as
5 PSI or 0.3 BAR if clean and supplied with 45
water.
Potable Water Inlet Flow Rate
1.25 GPM or 4.7 LPM
Water Cooled Condenser GPM
o
o
70
F or 21
C water: .25 GPM or .95 LPM
o
o
50
F or 10
C water: .11 GPM or .41 LPM
Voltage 115 volt models
Maximum 126 VAC
Minimum 104 VAC
Electrical
Model
(Volts/Hz/Phase)
UC2024SA-1A
115/60/1
UC2024MA-1A
115/60/1
UC2024SW-1A
115/60/1
UC2024MW- 1A 115/60/1
UC2724SA-1A
115/60/1
UC2724MA-1A
115/60/1
UC2724SW-1A
115/60/1
UC2724MW-1A
115/60/1
o
C
o
C
o
C
o
C
Condenser
Air
Air
Water
Water
Air
Air
Water
Water
Operating the machine outside of any of the above
limitations is considered abuse and any resulting
damage is not covered by warranty and could cause a
complete loss of warranty coverage.
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage.
In general, warranty covers defects in material
or workmanship. It does not cover maintenance,
corrections to installations, or situations when the
machine is operated in circumstances that exceed the
limitations printed above.
Product Information:
The UC is available in two cube sizes. The ice size
cannot be changed significantly. The ice is stored
in an insulated bin with ice level automatically
maintained by the control system.
A back flow preventer may be required by local
o
plumbing codes.
F
115 volt models include a 5.5 ft. power cord with
NEMA 5-15P plug.
Air cooled models flows in the right front and out the
left front and include a cleanable air filter.
Legs are provided, thread size is 5/8-11. Replacement
leg kit number is KLP7.
Machine may be installed without legs.
For available options and kits, see sales literature.
Maximum Fuse
Cube
Size or Breaker
Size
(Amps)
Small
15
Medium
15
Small
15
Medium
15
Small
15
Medium
15
Small
15
Medium
15
November 2019
Page 3
Refrigerant
Power Cord
Charge (oz)
Termination
(R-134a)
5-15P plug
15
5-15P plug
15
5-15P plug
12
5-15P plug
12
5-15P plug
14
5-15P plug
14
5-15P plug
11
5-15P plug