Specifications And Location Information - Scotsman EH222 Quick Start Manual

Prodigy eclipse cuber with ecc condensing unit
Table of Contents

Advertisement

EH222 and Condensing Unit
Remote Low Side Cuber Service Manual

Specifications and Location Information

Model
Electrical
volts/Hz/phase
EH222SL-1C
115/60/1
ECC0800-32
208-230/60/1
ECC0800-3
208-230/60/3
ECC1410-32
208-230/60/1
ECC1410-3
208-230/60/3
* See cabinet drawings for detailed dimensions.
Location Limitations
Maximum Distance between Head and Condensing
Unit: Limited to the length of the longest available
single tubing kit, 75 feet.
Maximum Condensing Unit Elevation over Ice Making
Head: 35 feet.
Note: Elevations greater than 20 feet require
installation of a suction line trap at the 20 foot mark.
Maximum Ice Making Head Elevation over
Condensing Unit: 15 feet.
Line Routing:
Allowed: One rise after a drop.
Allowed: One drop after a rise.
Not Allowed: More than one rise after a drop
Not Allowed: More than one drop after a rise.
Model Number Locations
Ice Making Head
The dataplate on the back of the ice machine contains
the model number, serial number and electrical data.
A second plate, located behind the front panel at
the lower right front, also lists the model and serial
numbers.
Minimum
Maximum
Circuit
Fuse Size
Ampacity
1.13
15
14.8
20
10.6
15
14.5
30
9.1
20
Condensing unit
The dataplate on the end contains the model number,
serial number, electrical data and system refrigerant
charge.
A second plate, located behind the side panel on the
deck, also lists the model number, serial number and
refrigerant charge.
August 2013
Page 4
System Charge,
Cabinet Size*
oz of R-404A
w" x d" x h"
shipped w/none
22 x 16.5 x 29
192
32 x 39 x 39.75
192
32 x 39 x 39.75
224
32 x 39 x 39.75
224
32 x 39 x 39.75
Unit Weight