ELECTRONIC FLAKER MODEL AF 80
ice making capacity
AIR COOLED MODELS
K g .
7 5
7 0
6 5
6 0
5 5
5 0
4 5
21
32
WATER TEMPERATURE
NOTE. With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graph, up to a maximum of 10% at room temperatures higher than 32 ° C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN FLAKER at peak performance levels, periodic maintenance checks
must be carried out as indicated on page 32 of this manual.
SPECIFICATIONS
o
°C
10
21
32
38
o
15
°C
Important operating requirements:
- Air temperature
10°C (50°F)
- Water temperature
5°C (40°F)
- Water pressure
1 bar (14 psi)
- Electr. voltage
variations fromvoltage
rating specified
on nameplate
WATER COOLED MODELS
K g .
7 5
7 0
6 5
6 0
5 5
5 0
4 5
32
WATER TEMPERATURE
Page 3
MIN
MAX
40°C (100°F)
40°C (100°F)
5 bars (70 psi)
-10%
+10%