L3 FA2100 CVR Component Maintenance Manual With Illustrated Parts List page 209

Cockpit voice recorder
Table of Contents

Advertisement

(w) Click on Yes. The autotest will now proceed in completing the autotest
(x)
NOTE: The test report is named with the part number of the Unit Under Test and
the serial number provided in the Information section of the test. The test
report is located in the following default location: C:\Program
Files\L−3Com\CVRTester\Reports. This file is in an ASCII text file format.
(y)
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AVIATION RECORDERS
COMPONENT MAINTENANCE MANUAL
FA2100CVR
Figure 174. CATS, CVDR Fault History Log
which will take approximately 30 minutes or less.
Figure 175. CATS, Continue Test Confirmation
At the end of the test, save the report by selecting File => Test Report =>
Save Report.
If the autotest is successful, clear the fault history log by the pull down
menu, click on Test=>Clear Fault History.
23–70–04
Testing & Fault Isolation
Rev. 15 Page 160
Apr. 14/16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents