PS5500 Environmental Requirements

You must meet these environmental requirements:
Only operate an enclosure from a power source with a voltage range of 100 to
240 VAC.
Make sure your power source has sufficient electrical overload protection.
In North America, connect the enclosure to a source of power with over-
current protection provided by a double pole 20A or less (LISTED circuit
breaker to UL489). In Europe, the over-current protection must be provided
by 20A or less (IEC circuit breakers).
Have sufficient space for air flow in front of and behind the array and ensure
that the location is properly vented.
Follow the PS5500 technical specifications. See Table 2-6.
Table 2-6: PS5500 Technical Specifications
Component
Weight without disk drives
Weight with disk drives
Operating temperature
Storage temperature
Operating altitude
Operational relative humidity
Storage relative humidity
Thermal output (fully-loaded array) 3400 BTU/hour
Operational shock
Operational vibration
Input voltage
Input frequency
System input power
Each power supply
Height/Width/Depth
Requirement
77 pounds (35kg)
177 pounds (80kg)
41 to 95 degrees F (5 to 35degrees C)
34 to 140 degrees F (1 to 60 degrees C)
0 to 10,000 feet (0 to 3048 meters)
20% to 80% non-condensing
5% to 80% non-condensing
5g peak 1/2 sin, for 10ms
.21grms 5 to 500 Hz Random
100 to 240 VAC (auto-sensing)
50 - 60Hz
1400 VA (maximum)
440 watts DC output
Maximum input power: 0.7 KVA
Input current: 7 – 3.5A
6.89" x 19.01" x 31.9" (17.5cm x 48.3cm x 81.0cm)
Installing Array Hardware
2–13