MUX DVBS2 - IP CI / MUX DVBT2 - IP CI
5. - Instruction for Use
Connecting to the unit's web control interface
The unit's IP must be known to access its control interface. The default IP address of the unit is printed in the rear label.
Connect a PC directly to the module's ETH1 port with an Ethernet cable. Configure the PC's IP address on the same subnetwork
as the module.
Open a browser (Mozilla Firefox or Google Chrome recommended) and go to the URL https://<module IP>
The unit can also be connected via Wi-Fi using adapter kit ref 216802. This adapter must be connected to the micro USB port
on the front of the unit. After an automatic initialization process, connection to a Wi-Fi network will be possible. Its SSID has the
following format: Televes_mng_XXYYZZ, where XXYYZZ corresponds to the final digits in the unit's MAC address. To go to the
configuration website, open a browser and go to the URL "config.t0x".
The default login credentials for website access are: username: "web" and password "admin".
Assembly recommendations
To simplify initial headend configuration, follow the steps indicated below:
- Disconnect the power supply from the socket.
- Order the modules in ascending IP order.
- Connect the input signals (satellite or terrestrial) to the front input F connectors.
- Connect the units' ETH2 outputs to the external video distribution switch with Ethernet CAT6 cables. Another option is to cre-
ate a loop between one unit's ETH2 connectors and the ETH1 of the next one, and only connect the ETH2 connector of the last
module as shown in point 3.1.
- Connect the PC to the first module (lowest IP) as explained in the previous point. This unit must be configured as the Master
and will be the point of access to the entire headend. All information on the other units connected to the Master data network
(ETH2) will be visible on the interface of the unit configured as the Master. Units that are not the Master will only have their own
configuration available.
IMPORTANT: A single Master must be configured in the headend, which will be marked with an "M" on all setup screens.
- Connect the powering hoses splitting consumption between the two power supply outputs (see point 3.1)
- Connect the power supply once all the above connections have been made.
Unit control interface
The control interface is divided into the following areas:
- The menu bar is shown to the left.
- The upper right-hand section shows the language selection.
- The middle section shows the different control forms based on the selected menu.
Each setup screen includes the apply configuration button to send data to the unit. If the screen is changed and the changes
were not applied, a warning message will appear.
NOTE: The screenshots shown here have several units (lines) on each menu. This only occurs if the unit is configured as the Mas-
ter. Otherwise, only the data on the unit being physically connected will be shown.
The available options are:
Status Menu
This screen shows information about:
- Inputs used by the headend, including frequency, engagement, and quality measures.
- CAMs inserted in the modules: name and status.
- IP outputs: list of configured services, including the bitrate and the encryption status.
10