MUX DVBS2 - QAM/COFDM CI Twin Contents Technical specifications ................................... References’ description ..................................Installation ......................................3.1. Wall mount ....................................3.2. 19 inch rack ....................................Elements’ description ..................................4.1. Introduction ....................................4.2. Power Supply Unit ..................................4.3. Amplifiers ....................................4.4. Programming Unit ................................... Instructions for use ....................................
Page 4
Hereby, Televés S.A.U. declares that the radio equipment type “MUX DVBS2 - QAM CI / MUX DVBS2 - COFDM CI” is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://doc.televes.com.
1. Technical specifications 1.1. MUX DVBS2-QAM CI Twin Ref. 564401, MUX DVBS2-COFDM CI Twin Ref. 564301 Input frequency 950 - 2150 Through losses (typ.) < 1.5 Symbol rate Mbaud 2 - 45 DVB-S2 QPSK, 8PSK Modulation Frequency steps DVB-S QPSK Satellite IN/OUT connectors tipo...
Page 6
MUX DVBS2_QAM/COFDM CI Twin 530 (564301) 540 (564401) => (LNB not powered/ CAM not inserted) 630 (564301) 640 (564401) => (LNB not powered/ CAM inserted) Consumptions @ 24Vdc (with signal)* General 880 (564301) 890 (564401) => (one LNB powered/ CAM inserted) 1130 (564301) 1140 (564401) =>...
Page 7
1.3 Power Supply Unit technical specifications Total maximum current Mains voltage/frequency V~ / Hz 196 - 264 / 50-60 5 (24V (OUT1 + OUT2) PSU Ref. 5629 Output voltage Maximum current per output 4 (24V 1.4 Block diagram Ref. 564401 Demodul.
3 Installation 3.1 Wall mount SAT IF 564401, 564301 5629 5575 INPUT CLAC! 5071 OUTPUT COFDM (564401) (564301) 4061 7234 NOTE: The use of both PSU power outputs is recommended to balance the consumption. For example, 4+3 or 3+4.
MUX DVBS2_QAM/COFDM CI Twin 4.2 Power Supply Unit Connectors to power the modules (1) Status LED 24V: OK 0V: Overload or short circuit 02340039001 003 Mains input 230V~ REMARKS • The power supply can power up to a maximum of 7 modules with CAM, and being active only 2 LNB feeds of the assembly of seven multiplexer. •...
4.3 Amplifiers OPTION “A” - 5575 OPTION “B” - 451203 TEST (-30dB) +10 dB OK - MATV 20 dB 20 dB 10 dB 10 dB 20 dB MATV OK - Return USO EXCLUSIVO EN INTERIOR C. Ret C. Ret FOR INDOOR USE ONLY ¡¡¡ATENCIÓN!!! NO ABRIR.
MUX DVBS2_QAM/COFDM CI Twin 4.4 Programming Unit PCT 5.0 The programming unit features 4 buttons: (short press) - Selection of P C T 4 . 0 parameter (positioning of the U N I V E R S A L cursor). Modification of the parameter chosen by the cursor (flashing).
5 Instructions for use 5.1 Standard menu DVB-S signals is automatic. These parameters will be active when the option Connect the programming unit to the front socket “Enabled” is selected 5.1.a Input menu of the module (“PRGM”). These parameters are only operational when At first, the controller’s firmware version will you select the option ‘Enabled’...
Page 16
MUX DVBS2_QAM/COFDM CI Twin 5.1.c Output menu 1QAM 1COFDM Mod: 256QAM 8MHz 64QAM Next main menu shows the output frequency/ normal GI:1/8 channel, the output level control and the output Baud:6.900Mb FEC:3/4 mode selection, for each of the outputs. The available options for this menu as well as their SALIDA SALIDA 2OUTPUT...
Page 17
5.1.d Identifiers menu Once the search has completed, it is displayed a list in the output (configured as DCY). of services. Each service is part of a list containing Scrambled service in the input, and free all services found in the 3 input channels. The Since each of the output transport stream is formed service in the output (configured as DCY).
Page 18
MUX DVBS2_QAM/COFDM CI Twin 5.1.e.1 PIDs menu become the actual value to take into account, to indicate, at all times, which is the input that which may vary slightly from the estimate. provides the current service. II. Direct access to the services of a particular input To access this menu, within the service menu make Note: When the number of services exceeds 100, it is by selecting the identifier of one of the A/B/C...
Page 19
• » OFF It is not allowed to pass to the output It also shows the peak reached, which Description of the PID function: can be reset by pressing on key. » DCY It passes to the output and requests »...
MUX DVBS2_QAM/COFDM CI Twin 5.2 Extended menu two modes available to program the output unit has been assigned a unique address on the bus, or the units will not communicate. The valid frequency. Choices are: a) By entering the address range goes from 1 to 254 (which is the channel frequency value, and b) by selecting To access this menu make a long press on maximum number of devices controllable from...
Page 21
CONFIG CONFIG CONFIG CONFIG LOOP: ON LOOP: ON LOOP: ON LOOP: ON LNB : 17V ~ LNB : 17V ~ LNB : 17V ~ LNB : 17V ~ 5.2.b Configuration menu 2 be applied either for demodulator A or TEMPERATURA TEMPERATURE demodulators B and C.
Page 22
MUX DVBS2_QAM/COFDM CI Twin » IN A Can be unscrambled services from input » ON SAFE When the user configure and VERSION A, only. saves a number of PIDs, the safe mode FW:2.02 sets this number as the maximum of »...
Page 23
5.2.f CAM user interface menu (MMI) 1SID On the upper of the display is displayed the index A. Direct This menu provides access to the user interface (order) of the current service and the total number Start of them at the output. Next is shown the service conditional access module (CAM), for example, to 1003000001! name.
Page 24
EPG will be more complete. On the specify the desired name. contrary, if Full EPG is selected to OFF, only the By default the network is called “TELEVES”. information of the current event and the next one (EIT Present / Following tables) will appear.
5.3 Saving parameters 6. Device control The ON LEDs indicate correct operation of both inputs or outputs. After setting up the unit by means of the two menus available, main and extended, all data will This version of modules allows configuration and Note: LED C will turn OFF if it fails to decrypt any be saved by pressing the button for about 3...
Page 26
CAM 2LCN 1SID LCN TYPE NET NAME 1VERS. PSI LANGUAGE SELECT LOOP: OFF Now: FW:1.00.4 POS:OUT1 Press A. Direct TELEVES Vers NIT: 28 DEFAULT LNB: BC Max: Mod:1.00.9 DCY SEcURe: menus Fashion TV Start Generic Vers SDT:AUT English SETTINGS SAT: B 13V...
MUX DVBS2_QAM/COFDM CI Twin 8. Norms for rack mounting (Max. 49 MUX CI T-0X - 7 subracks with 5 units in height - 8,7”) 8.1. Installation of the rack with These ventilators will be installed on a tray that is fixed inside the cabinet (fig.
Page 29
8.2. Installation of the rack without It is very important that this process operates co- rrectly, therefore the following must be observed: ventilation facilities - Do not open the side doors, as this would cause the ventilators to extract the air from the outside To install the units in racks without installation rather than the air inside the rack.
MUX DVBS2_QAM/COFDM CI Twin 9. Norms for cabinet mounting IMPORTANT EXTRACTOR for forced The scheme of recommended ventilation must be onto ventilation is the one in the figure the highest module. in any case of cabinet placement (horizontal or vertical). Maximum environment temperature: 45ºC.
Page 31
IMPORTANT Horizontal placement of the cabinets is strongly recommended, hanging them as HORIZONTAL near to the floor as possible. If the horizontal placement is impossible, 0,2 m then vertical placement is allowed. 0,2 m Respect the recommended minimum distances in the attached schemes. 0,8 m Maximum T: 45ºC.
Need help?
Do you have a question about the T.OX 564301 and is the answer not in the manual?
Questions and answers