  • Page 1 Ref. 563401 User manual COFDM - COFDM CI w w w . t e l e v e s . c o m...
  • Page 3: Table Of Contents

    COFDM-COFDM CI Index Technical specifi cations ........................Reference description ......................... Mounting ............................. 3.1. Wall mounting ..........................3.2. 19” rack mounting ........................Element description ..........................4.1. Introduction ..........................4.2. Power supply unit ........................4.3. Amplifi er ..........................4.4. Universal programmer ......................How to use the product ........................
  • Page 5: Technical Specifi Cations

    1. Technical specifi cations 1.1. COFDM-COFDM CI ref. 563401 177,5 - 226,5 (VHF) (Select.) Input frequency Input VSWR dB typ. >10 474 - 858 (UHF) Input connectors type “F” female Bandwidth 7, 8 COFDM input Frequency steps 125, 166 (Select.) Through loss dB typ.
  • Page 6 COFDM - COFDM CI 1.2. Technical specs. Broaband Amplifi ers Frequency range 46 ... 862 MHz Connector “F” Gain 44 ± 2,5 dB Powering voltage 24 V Amplifi er 5575 Regulation margin 20 dB 450 mA Consumption at 24 V Output level (60 dB) 105 dBμV (42 CH CENELEC) Test socket...
  • Page 7: Reference Description

    2. Description of references Product range Accessories 563401 COFDM-COFDM CI T-0X 7234 Universal Programmer 5575 Broadband Amplifi er 44dB 120dBμV T-0X 5071 T03-T05-T-0X Mounting rail (50 cm) 451202 Amplifi er DTKom (47 - 862 MHz) 5239 T03-T05-T-0X Mounting rail.12 Modules+PSU (56 cm) 5559 Headend Manager CDC-IP T-0X 5301...
  • Page 8: Mounting

    COFDM - COFDM CI 3. Mounting 3.1. Wall mounting COFDM 563401 5629 5575 input CLAC! 5071 5239 UPSU120 COFDM output 4061 7234 NOTE: The use of both source outputs is recommended, balancing the consumption. For example, 4+3 or 3+4 modules...
  • Page 9: 19" Rack Mounting

    3.2. 19” rack mounting 5301 UPSU120...
  • Page 10: Element Description

    COFDM - COFDM CI 4. Identifi cation of the system elements 4.1. Introduction CTRL PRGM 1. COFDM input 6. Status LED Insert the smart card completely into the CAM slot before powering 2. COFDM output 7. Control BUS connectors modules. Card contacts looking 3.
  • Page 11: Power Supply Unit

    4.2. Power supply unit Connectors to power the modules (1) On LED 24V: OK 0V: Overload or short circuit UPSU120 Mains input 230V~ NOTES: - The PSU can power a maximum of fourteen COFDM-COFDM CI modules. - Whenever the demand of power exceeds 4A (max. current for each output), it is necessary to distribute it between the two powering outputs of the PSU.
  • Page 12: Amplifi Er

    COFDM - COFDM CI 4.3. Broadband amplifi er OPTION “A” - 5575 OPTION “B” - 451202 TEST (-30dB) +10 dB OK - MATV 20 dB 20 dB 10 dB 10 dB 20 dB MATV OK - Return USO EXCLUSIVO EN INTERIOR C.
  • Page 13: Universal Programmer

    4.4. Universal Programmer PCT 5.0 The programmer features 4 buttons: (short press) - Selection of parameter (posi- tioning of the cursor). P C T 4 . 0 Modifi cation of the parameter chosen by U N I V E R S A L the cursor (fl ashing) (short press) - Change menu...
  • Page 14: How To Use The Product

    COFDM - COFDM CI 5. - Instructions for use 5.1. Normal menu input connector (line power set to ON) the frontal LED will be blinking until it is fi xed. Insert the programmer in the front connector of the module (“PRGM”). First, the programmer’s a.
  • Page 15 c. Service menu channel from the table selected as well as the Statistics (xx/yy) indicate the following: the fi rst off set regarding the central channel frequency. The number indicates the percentage of the output permitted off set values depend on the frequency This menu shows the list of input transport stream occupied by the service.
  • Page 16: Extended Menu

    COFDM - COFDM CI f. Measurements menu 3 5.2. Extended menu The following menu provides an indication of When the key is held down for more than 3 the unit’s current temperature as well as the seconds the unit shows a series of less frequently maximum recorded.
  • Page 17 b. Frequency steps menu If the service already has an assigned LCN in the input it is allowed to change or remove the LCN in the output tables, selecting 0000 as the LCN. “NO This menu lets you select the frequency steps that LCN”...
  • Page 18: Parameters Saving

    COFDM - COFDM CI 5.3. Parameters saving 6. - Controlling the Device Finally, the LEDS indicate the following operating conditions: - Left LED (A) = The level of the input signal is This version of the COFDM-COFDM CI allows Once a parameter is modifi ed to the desired value suffi cient (for guidance).
  • Page 19 Menu structure Long press...
  • Page 20: Distribution Of 7 Channels

    COFDM - COFDM CI 7. Application example Distribution of 7 channels of COFDM-COFDM CI 75 ohm 4061 451202 7 x 563401 5629 COFDM output The diagram shows the assembly for the distribution of 7 channels of COFDM-COFDM CI...
  • Page 21: Norms For Rack Mounting

    8. Norms for rack mounting (max. 49 COFDM-COFDM CI - 7 subracks with 5 units in height - 8,7”) 8.1. Installation of the rack with These ventilators will be installed on a tray that is fi xed inside the cabinet (fi g. 1 & 2). This way, the ventilation facilities ventilators will force the fresh air entering from the base of the cabinet, to circulate between the...
  • Page 22 COFDM - COFDM CI 8.2. Installation of the rack without It is very important that this process operates correctly, therefore the following must be ventilation facilities observed: - Do not open the side doors, as this would cause To install the units in racks without installation the ventilators to extract the air from the outside facilities, and when the rack is located in a place rather than the air inside the rack.
  • Page 23: Norms For Cabinet Mounting

    9. Norms for cabinet mounting IMPORTANT EXTRACTOR for forced ventilation must be onto The scheme of recommended the highest module. ventilation is the one in the fi gure in any case of cabinet placement (horizontal or vertical). Maximum environment temperature: 45ºC. Horizontal The maximum temperature placement...
  • Page 24 COFDM - COFDM CI IMPORTANT Horizontal placement of the cabinets is strongly recommended, hanging them as HORIZONTAL near to the fl oor as possible. If the horizontal placement is impossible, 0,2 m 0,2 m then vertical placement is allowed. Respect the recommended minimum distances in the attached schemes.
  • Page 25: Channels Table

    A. Channels table Tabl. 1 Tabl. 2 Tabl. 3 Tabl. 4 Tabl. 5 Tabl. 6 Tabl. 7 Tabl. 8 Tabl. 9 Tabl. 10 CCIR China/Taiwan Chile Italy France OIR channels Ireland South Africa Poland (OIR) Australia 50,50 52,50 57,00 56,00 45,00 52,50 48,50...
  • Page 26 COFDM - COFDM CI 314,00 658,00 611,00 346,00 346,00 354,00 674,00 658,00 394,00 296,50 322,00 666,00 617,00 354,00 354,00 362,00 682,00 666,00 402,00 305,50 330,00 674,00 623,00 362,00 362,00 370,00 690,00 674,00 410,00 312,50 338,00 682,00 629,00 370,00 370,00 378,00 698,00 682,00 418,00...
  • Page 27 642,00 857,00 674,00 674,00 682,00 722,00 585,50 650,00 863,00 682,00 682,00 690,00 730,00 592,50 658,00 690,00 690,00 698,00 738,00 599,50 666,00 698,00 698,00 706,00 746,00 606,50 674,00 706,00 706,00 714,00 754,00 613,50 682,00 714,00 714,00 722,00 762,00 620,50 690,00 722,00 722,00 730,00 770,00...
  • Page 28 COFDM - COFDM CI...
  • Page 29 Guarantee Televés S.A. offers a two year guarantee, beginning from the date of purchase for countries in the EU. For countries that are not part of the EU, the legal guarantee that is in force at the time of purchase is applied. Keep the purchase invoice to determine this date. During the guarantee period, Televés S.A.