Download Print this page

Storing A Program - PhotoCentric CURE M User Manual

Advertisement

Program : Basic
The Big program is designed for drying large
objects that take up most of the drying volume.
The UV emission is 100% of its power and the
exposure time is 90 minutes. The temperature
curve will reach 40 ° C during the program. The
program starts by clicking on the BIG icon on the
icon.
The program Custom and
memorization
The Photocentric Cure M can store 7 personalized
programs (0-6) within its user interface.
The Custom programs will allow you to save your
most used polymerization processes without
having to enter the values into the CURE M each
time. The Custom program also allows you perform
the below:
Adjust UV power from 1% up to 100%.
Adjust the exposure time from 1 second to 100
hours. The temperature from 20 ° C to 60 ° C (which
will be reached during the program).
Clear Program.
The Clear program is designed for drying objects
produced with transparent and delicate resins. The
UV emission is reduced to 10% and the exposure
time is 20 minutes. The program starts by clicking
on the CLEAR icon.
CU RE M

Storing a program

Click on Custom and display the program list
choose the number of the program you want to
edit and save, once the program has been selected
click on Set PRG and set the parameters you want
and return to the program list.
Check that the program shows the values you have
set by clicking again on the set program and then
start the program with START.
During the program you can stop it by clicking on
STOP or put it in PAUSE. At the end of the process
the display will indicate the process is complete.
Caution:
Only if you return to the program list will yours be
stored if you select.
Start after changing programs without returning to
the program list.
It will be valid only for that work cycle and will not be
stored.
CU R E M

Advertisement

loading