Define the area of installation
Concentrate the number of fasteners
in edge and corner zones.
Further recommendations are
offered in the structural analysis.
Mount fasteners
Select corresponding distance a
between fasteners for the respective
module. Measurement a is derived
from the module width plus 24 mm.
Distance between fasteners b should
be taken from the structural analysis
for fasteners - schematic diagram is
displayed in Autokalkulator.
Further recommendations are
offered in the structural analysis (for
fasteners).
The number of fasteners required is
also dependent upon the properties
of the roof - please verify details with
the manufacturer!
We recommend the use of a fas-
tener with a slotted hole (e.g. Fix2000
standard). Measurement a can there-
fore be optimally adjusted.
LAQ07 can be installed if the distanc-
es between module-bearing profiles
can be precisely set - e-g- trapezoidal
sheet metal roofs, seamed roofs and
cross rails.
2
LaQ07 Laminate Mounting Instructions
e/10
e/4
e/4
e/10
Building
Calculation formula:
e = min (x / y or 2
© Schletter GmbH
Gewerbegebiet an der B15
•
Fax: +49 8072 9191-9200
E-mail: solar@schletter.eu
•
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: info@schletter.co.uk
Corner zone
Edge
zone
Corner zone
e/10
e/4
h
.
h)
a
Alustraße 1
83527 Kirchdorf/Haag i. OB
•
•
www.schletter.eu
•
x
Edge zone
Corner zone
Field zone
Edge zone
Corner zone
b
Germany
Tel.: +49 8072 9191-200
•
•
Updated 04/2012
Subject to change without notice
•
•
GB
Edge
y
zone
e/10
e/4