Download Print this page

Gira Observer 110 Manual page 8

Advertisement

Observer 110
Connecting controllers in parallel
o
Connect controller and optional installation button according to connection diagram ( 9).
5.2 Commissioning
Checking the detection area
o
Switch on test operation ( 4. Operation).
o
Pace off the detection area, paying attention to reliable detection and interference sources.
o
If necessary, limit the detection area to mask out interference sources. To do this, adjust
the sensor head or use a cover plate ( 4. Operation).
Making operation settings
For detailed information, see the chapter Operation ( 4. Operation).
o
Switch on automatic mode.
o
Set brightness threshold.
o
Set follow-up time.
6 Appendix
6.1 Technical data
Rated voltage
Mains frequency
Power consumption
Ambient temperature
Protection rating
Circuit breaker
Installation height
Detection angle
Range
run-on time
Follow-up time (test)
Lockout time
Brightness setting
Connected load
Incandescent lamps
HV halogen lamps
Tronic transformers
82508412
9: Connecting controllers in parallel
19.05.2011
approx. 12 s ... 12 min
approx. 5 ... 300 lx (and day operation)
AC 230 V ~
50 Hz
approx. 1.3 W
-35 ... 50 °C
IP 54
max. 10 A
2.5 m
approx. 110 °
approx. 16 m
approx. 1 s
approx. 2 s
2200 W
1000 W
Type-dependent
8/10

Advertisement

loading

This manual is also suitable for:

0355 02