Settings

9
9.1

Description of the adjustable Prameter

9.1.1 General Parameters

Parameter
IP Address
Network mask
Gateway
Baud rate
Language
Torque unit
Main direction of rotation
Rotation speed decrease
Signal sound
Password
Date / Time
Offset gear
Gear
transmission
ratio
Efficiency
Direction change Specifies whether the adapter gear causes change of
Description
The IP address via which the AST6 can be reached in
the network.
It indicates the network segment in which the
sequence controller AST6 is located.
The IP address of the gateway for the network
segment in which the sequence controller AST6 is
located.
You are able to adjust whether the Ethernet
connection with 10 Mbits/s should process or if it
should automatically adjust to the network.
The language that should be displayed in the web
interface as well as also the operating interface of the
sequence controller AST6.
The torque unit that is used for display and settings of
torque values. Available units are:
• N·m
• in·lb.
• N·cm
• kg·m
• ft·lb.
• kg·cm
The main direction of rotation indicates what direction
is defined as screwing application. The main direction
right means that all screwing samples will operate
rotating to the right, all screw samples to release with
rotate to the left.
If the rotation speed decrease is active then the
torque screwing levels, that do not have torque
transfer occurring, will automatically lower the rotation
speeds when 80% of the target torque is reached.
This provides a higher cut-out accuracy.
determines under which conditions the signal sound
is released at the end of the screwing process.
The menus of the controller in which changes can be
performed can be password protected. The password
can be in a range of 0000 to 9999 and must be four-
digit.
If 0000 is set as a password then all menus at the
controller are freely accessible.
In delivery state the password is set to 0000.
Setting for the internal true clock of the controller.
Transmission ratio for the adapter gear
Effectiveness of the adapter gear
direction.