Option settings
NT8D22 System Monitor
NT8D22 SW1
Not used
Meridian 1 columns only
Position 1 is OFF (Meridian 1 columns only)
Not used
Position 1 is ON, master column contains CP:
DC-powered system
AC-powered system
PFTU is activated by this column due to over-temperature
PFTU is not activated by this column
Position 1 is OFF (Meridian 1 columns only)
Not used
Not used
Position 1 is OFF (Meridian 1 columns only)
Not used
Not used
Not used
Not used
Not used
Meridian 1 columns only
553-3001-211 Standard 17.00 April 2000
The master system monitor, located in the column with CP 0, must be
numbered 0. Slave system monitors are numbered from 1 to 63.
For examples of system monitor option settings in basic configurations, see
"Sample settings for NT8D22 System Monitors."
Configure the system monitor in Remote Peripheral Equipment (RPE)
columns as slaves. There is no serial connection between RPE columns.
SW1 function
1
2
on
off
off
off
master
on
slaves
off
Position
3
4
5
6
on
off
on
off
off
on
off
off
on
off
7
8
on
on
on
off
off
on
off
off