TECHNICAL DATA

MODEL
TYPE
OUTPUT
MAX.°
(1)
MIN.
FUEL
- net calorific value
- absolute density
- max. delivery
- pressure at max. delivery (2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
ACCELERATION CURRENT
WORKING CURRENT
MOTOR CAPACITOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
PROTECTION LEVEL
NOISE LEVELS
SOUND PRESSURE
(3)
SOUND POWER
(1) Reference conditions: Room temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0m above sea level.
(2) Socket pressure 7)(A)p.4 with zero pressure in the combustion chamber.
(3) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output. The
sound power is measured with the "Free Field" method, as per EN 15036, and according to an "Accuracy: Category 3" measuring accuracy,
as set out in EN ISO 3746.

STRUCTURAL VERSIONS

MODEL
POWER SUPPLY
RS 25/M BLU
RS 35/M BLU

GAS CATEGORIES

DESTINATION COUNTRY
SE - FI - AT - GR - DK - ES - GB
IT - IE - PT - IS - CH - NO
DE
NL
FR
BE
LU - PL
kW
Mcal/h
kW
Mcal/h
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
9.45
kWh/Sm
3
Mcal/Sm
0.71
3
kg/Sm
3
Sm
/h
mbar
15,6
• Continuous.
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water, steam, diathermic oil
°C
0 - 40
°C max
60
V
230 ~ +/-10%
Hz
50/60 - single-phase
rpm
W
V
A
A
F/V
V1 - V2
I1 - I2
W max
dBA
BLAST TUBE LENGTH
Single-phase
Single-phase
Single-phase
Single-phase
Three-phase
Three-phase
GAS
CATEGORY
I
2H
I
2ELL
I
2L
I
2Er
I
2E(R)B
I
2E
RS 25/M BLU
876 T
125 - 370
108 - 320
45
39
G25
G20
8.13
9.45
8.2
7.0
0.78
0.71
39
45
21,8
14,1
2800
300
220 - 240
15
3.2
12.5/260
230 V - 1 x 15kV
1 A - 25mA
600
68
79
mm
230
365
230
365
230
365
2
RS 35/M BLU
877 T
202 - 480
174 - 413
72
62
G25
G20
8.13
9.45
8.2
7.0
0.78
0.71
51
59
24,7
14,1
230 - 400 with neutral ~ +/-10%
50/60 - three-phase
2800
420
220 - 240
17
3.5
12.5/420
700
IP40
70
81
RS 35/M BLU
877 T
202 - 480
174 - 413
72
62
G25
8.13
8.2
7.0
0.78
51
59
24,7
2780
450
220/240-380/415
14 - 10
2 - 1.4
-
750
70
81