Pentair PTS Jung Multicut 08/2 ME Instruction Manual
Pentair PTS Jung Multicut 08/2 ME Instruction Manual

Pentair PTS Jung Multicut 08/2 ME Instruction Manual

Hide thumbs Also See for PTS Jung Multicut 08/2 ME:

Advertisement

Quick Links

PTS/Jung Multicut
08/2 ME
08/2 MES
08/2 M, EX
EN Instruction Manual
Pump Technical Services Limited - Pump House - Unit 12 - Bilton Road
Industrial Estate - Erith - Kent - DA8 2AN
Tel: 01322 357 080 - Fax: 01322 341 341 - Email: sales@pts-jung.co.uk
B 43214-14-1506
08/2 M
08/2 MS
20/2 M PLUS
08/26 M
08/26 MS
20/2 M PLUS, EX
www.pts-jung.co.uk
1

Advertisement

Table of Contents
loading

Summary of Contents for Pentair PTS Jung Multicut 08/2 ME

  • Page 1 PTS/Jung Multicut 08/2 ME 08/2 M 08/26 M 08/2 MES 08/2 MS 08/26 MS 08/2 M, EX 20/2 M PLUS 20/2 M PLUS, EX EN Instruction Manual Pump Technical Services Limited - Pump House - Unit 12 - Bilton Road Industrial Estate - Erith - Kent - DA8 2AN Tel: 01322 357 080 - Fax: 01322 341 341 - Email: sales@pts-jung.co.uk www.pts-jung.co.uk...
  • Page 2: Safety Instructions For The Operator/User

    ENGLISH Qualification and training of You have purchased a product made by JUNG sories approved by the manufacturer is im- personnel PUMPEN and with it, therefore, also excel- portant for safety reasons. The use of other lent quality and service. Secure this service parts can result in liability for consequential All personnel involved with the operation, by carrying out the installation works in ac-...
  • Page 3: Areas Of Application

    ENGLISH AREAS OF without explosion protection may also Δ-Circuitry for low voltage (23291) be used. APPLICATION Modes of operation Submersible pumps in the MultiCut range are suitable for effluent in pres- with the pumped medium at a tem- sure drainage systems or for the drain- perature of 40°C: age of single dwellings.
  • Page 4: Installation

    ENGLISH Example installation with guide rail sponse temperature is reached. The tational direction is correct, the start-up motor is switched on again automati- jolt should be in the opposite direction system for pumping stations at a per- cally after the winding has cooled down. to the rotational direction arrow on the manent location.
  • Page 5 ENGLISH Checking the pump unit The pump must switch off when the wa- Motors in the EX range con- ter level sinks to the upper edge of the form to the "flameproof enclo- The housing screws for the pump, and pump housing (x in the illustration), at sures"...
  • Page 6 ENGLISH Checking the cutting clearance Tightening torque M for A2 screw ma- terials Using a suitable tool, e.g. feeler gauge, the cutting clearance between the cut- for plastic screw Torx Plus® 25 IP 5x12 ting rotor and the cutting plate can be MA = 2,5 Nm measured.
  • Page 7 08/2 ME 08/2 M, EX 08/2 MES 08/2 M 20/2 M PLUS 08/2 MS 20/2 M PLUS, EX 08/26 M 08/26 MS Performance   1   3   5   7   9  11  13  15  17  19  21  23 H [m] 08/2 ME(S) 16,5 15,0 13,0 11,0...
  • Page 8: Technical Data

    Technical data 08/2 ME /1 08/2 M /3 08/26 M /3 20/2 M PLUS [kg] 16,0 16,5 16,5 29,0 PN 6 DN 32 DN 32 DN 32 DN 32 [mm] 8 min. 8 min. 8 min. 12 min 10 % 10 % 10 % 25 %...
  • Page 9 Spare parts JUNG PUMPEN MULTICUT 08 JP46016 ① Capacitor JP46056 ② Contactor ③ Microswitch JP46351 230 V JP46352 400 V ④ Top cover JP46018 MS, MES JP46019 M, ME ⑤ Float JP46022 JP46020 ⑥ Switch shaft JP46025 ⑦ Switch cartridge ⑧...
  • Page 10 Spare parts JUNG PUMPEN MULTICUT 08/2 M, EX - 20/2 M PLUS - 20/2 M PLUS, EX ① Cable JP46259 JP45469 Ex, 10m JP45583 Ex, 15m JP45584 Ex, 20m ② Shackle JP45904 Stator + Housing ③ 08/2 JP43737 20/2 JP43738 JP46572 ④...
  • Page 11 DE · Konformitätserklärung FR · Déclaration de Conformité RO · Declaraţie de conformitate CZ · Prohlášeni o shodě HU · Megfelelöségi nyilatkozat SE · Försäkran om överensstämmelse DK · Overensstemmelseserklæring · Dichiarazione di conformità SK · Vyhlásenie o zhode EN · Declaration of Conformity NL ·...
  • Page 12 DE · Konformitätserklärung FR · Déclaration de Conformité RO · Declaraţie de conformitate CZ · Prohlášeni o shodě HU · Megfelelöségi nyilatkozat SE · Försäkran om överensstämmelse DK · Overensstemmelseserklæring · Dichiarazione di conformità SK · Vyhlásenie o zhode EN · Declaration of Conformity NL ·...
  • Page 13 ENGLISH 0197 JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany 417.12.1504 EN 12050-1:2001 Lifting plant for wastewater containing faecal matter 08/2 ME (JP09312/1) 08/2 MES (JP09613/1) 08/2 M (JP09945/3) 08/2 MS (JP09946/3) 20/2 M PLUS (JP42765) 08/2 M, EX (JP42768) 20/2 M PLUS, EX (JP42766) 20/2 M PLUS, EX (JP45211) 20/2 M PLUS, EX (JP45212)
  • Page 18 Pump Technical Services Limited - Pump House - Unit 12 - Bilton Road Industrial Estate - Erith - Kent - DA8 2AN Tel: 01322 357 080 - Fax: 01322 341 341 - Email: sales@pts-jung.co.uk...

Table of Contents