CP-RIO3-04S Preface Table of Contents Revision History ......................ii Imprint ........................ii Disclaimer ........................ii Table of Contents ...................... iii List of Tables ......................v List of Figures ......................vii Proprietary Note ......................ix Trademarks .......................ix Environmental Protection Statement .................ix Explanation of Symbols .....................x For Your Safety ......................xi High Voltage Safety Instructions ................xi...
Page 4
Preface CP-RIO3-04S 2.1.6 Rear I/O Interface on CompactPCI Connectors rJ2 ......2 - 9 Installation ................3 - 3 3.1 Safety Requirements ................3 - 3 3.2 Initial Installation Procedures ..............3 - 4 3.3 Standard Removal Procedures ..............3 - 5 3.4 Installation of External Serial ATA Devices ..........3 - 6 Page iv ID 1036-1669, Rev.
Kontron without further notice. Trademarks Kontron, the PEP logo and, if occurring in this manual, “CXM” are trademarks owned by Kon- tron, Kaufbeuren (Germany). In addition, this document may include names, company logos and trademarks, which are registered trademarks and, therefore, proprietary to their respective owners.
Preface CP-RIO3-04S Explanation of Symbols Caution, Electric Shock! This symbol and title warn of hazards due to electrical shocks (> 60V) when touching products or parts of them. Failure to observe the pre- cautions indicated and/or prescribed by the law may endanger your life/health and/or result in damage to your material.
However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation. Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
CP-RIO3-04S General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the device, which are not explicitly approved by Kontron and described in this manual or received from Kontron’s Technical Support as a special handling instruction, will void your warranty.
As a result, the products are sold “as is,” and the responsibility to ensure their suitability for any given task remains that of the purchaser. In no event will Kontron be liable for direct, indirect or consequential damages resulting from the use of our hardware or software products, or documentation, even if Kontron were advised of the possibility of such claims prior to the purchase of the product or during any period since the date of its purchase.
Page 12
Preface CP-RIO3-04S This page has been intentionally left blank. Page xii ID 1036-1669, Rev. 1.0...
CPU board are required. For further information concerning possible compatibility with other 3U Kontron CompactPCI boards, please contact Kontron. The CP-RIO3-04S comes with two Gigabit Ethernet ports and one VGA (CRT) port on the front panel, two COM ports (COM1 on the front panel and COM2 onboard), two onboard SATA ports for connection to external SATA devices, one onboard peripheral control port and one Com- pactPCI connector for connecting the CP-RIO3-04S to the backplane.
• Fan speed control output • Power supply sleep mode output • Wake-up / sleep input CompactPCI One CompactPCI connector, rJ2 for connecting the CP-RIO3-04S to the backplane Temperature Range Operational: 0°C to +60°C Standard Storage: -55°C to +85°C Without any additional components Note ...
Customers desiring to perform further environmental testing of Kontron prod- ucts must contact Kontron for assistance prior to performing any such testing. This is necessary, as it is possible that environmental testing can be destructive when not performed in accordance with the applicable specifications.
Introduction CP-RIO3-04S Related Publications The following publications contain information relating to the CP-RIO3-04S. Table 1-3: Related Publications PRODUCT PUBLICATION CompactPCI Systems and CompactPCI Specification 2.0, Rev. 3.0 Boards Kontron CompactPCI Backplane Manual, ID 24229 All Kontron products Product Safety and Implementation Guide, ID 1021-9142 Page 1 - 8 ID 1036-1669, Rev.
Board Interfaces 2.1.1 VGA Interface The CP-RIO3-04S provides one 15-pin, D-Sub VGA connector, J7, on the front panel. This connector is used to connect an analog VGA (CRT) monitor to the CP-RIO3-04S. The following figure illustrates the D-Sub VGA connector J7.
CP-RIO3-04S 2.1.2 Gigabit Ethernet Interfaces Figure 2-2: Gigabit Ethernet Connector J10A/B The CP-RIO3-04S provides one dual Gigabit Ethernet connector J10A/B realized as two RJ-45 connectors. The interfaces provide automatic detection and switching between 10Base-T, 100Base-TX and 1000Base-T data transmission (Auto-Negotiation).
2.1.3 COM Interfaces The CP-RIO3-04S provides two COM ports, COM1 and COM2, for connecting RS-232 devices. COM1 is available on the front panel and is implemented as an RJ-45 connector, J2. COM2 is available onboard and is implemented as a 10-pin connector, J3.
Functional Description CP-RIO3-04S The following figure illustrates the onboard serial port connector J3 (COM2). Figure 2-4: Serial Port Connector J3 (COM2) COM 2 The following table indicates the pinout of the onboard serial port connector J3 (COM2). Table 2-4: Serial Port Connector J3 (COM2) Pinout...
Wake-up / sleep input Signal ground Note ... Pin 5 is an open drain output and has no pull-up resistor on the CP-RIO3-04S. Therefore, an external pull-up resistor is required for fan control operations. ID 1036-1669, Rev. 1.0 Page 2 - 7...
SATA connectors, J5 and J6, used to connect standard SATA devices via a SATA cable. A SATA II repeater is provided on the CP-RIO3-04S to improve the signal performance. The following figure and table provide pinout information for the SATA connectors J5 and J6.
The CP-RIO3-04S may be used only with CPU boards that have a compatible rear I/O CompactPCI connector pinout, such as the CP305, CP307 and CP308 from Kontron. Failure to comply with the above may result in damage to the CP-RIO3-04S or the CPU board. Figure 2-7:...
Functional Description CP-RIO3-04S Table 2-7: Rear I/O CompactPCI Connector rJ2 Pinout ROW Z ROW A ROW B ROW C ROW D ROW E ROW F PWR_BTN# / PWR_SLPS3# RIO_3.3V / in / in 1RXD / out 1DCD# / out 1DTR# / in...
Page 31
CP-RIO3-04S Functional Description Legend for Table 2-7: SATAx Serial ATA port Gigabit Ethernet port VGAx VGA signals COM1x COM1 port COM2x COM2 port PWRx Power Management signals 5V/3.3V Power GPIO_CFG0 GPIO configuration (configured for COM2) ID 1036-1669, Rev. 1.0 Page 2 - 11...
Page 32
Functional Description CP-RIO3-04S This page has been intentionally left blank. Page 2 - 12 ID 1036-1669, Rev. 1.0...
CP-RIO3-04S. Ensure that there are no other external voltages or signals being applied to the CP-RIO3-04S or other boards within the system. Failure to do so could endanger your life or health and may damage the CP-RIO3-04S or other system components including process-side signal conditioning equipment.
Installation CP-RIO3-04S Initial Installation Procedures The following procedures are applicable only for the initial installation of the CP-RIO3-04S in a system. To perform an initial installation of both the CP-RIO3-04S in a system, proceed as follows: 1. Ensure that the safety requirements indicated in Chapter 3.1 are observed.
5. Disengage the CP-RIO3-04S from the backplane by first unlocking the ejection handle and then by pressing the handle as required until the CP-RIO3-04S is disengaged. 6. After disengaging the CP-RIO3-04S from the backplane, pull it out of the slot. 7. Dispose of the CP-RIO3-04S as required.
CP-RIO3-04S Installation of External Serial ATA Devices Up to two external SATA devices may be connected to the CP-RIO3-04S via the onboard SATA connectors J5 and J6 as well as the appropriate SATA cables. Some symptoms of incorrectly installed SATA devices are: •...
Need help?
Do you have a question about the CP-RIO3-04S and is the answer not in the manual?
Questions and answers