G9SX-NSA222-T03-@
Signal name
Terminal
name
Power supply input A1, A2
Connect the power source to the A1 and A2 terminals. Connect the power supply plus (24 VDC) to the A1 terminal.
Safety input 1
T11, T12
To set the safety outputs in the ON state, the high state
signals must be input to both safety input 1 and safety
input 2. Otherwise the safety outputs cannot be in the
ON state.
Safety input 2
T21, T22
Non-contact Door
D1, D2,
All Non-contact Door Switch inputs connected to the
Switch input
D3, D4
G9SX-NS must be ON as a required condition for the
safety outputs to be ON.
Otherwise the safety outputs cannot be in the ON state.
Feedback/reset
T31, T32,
To set the safety outputs in the ON state, the ON state
input
T33
signal must be input to T33.
Otherwise the safety outputs cannot be in the ON state.
To set the safety outputs in the ON state, the signal in-
put to T32 must change from the OFF state to the ON
state, and then to the OFF state. Otherwise the safety
outputs cannot be in the ON state.
Logical AND
T41, T42,
A logical AND connection means that one unit (Unit A)
connection input
T51, T52
outputs a safety signal "a" to a subsequent unit (Unit B)
and Unit B calculates the logical AND (i.e., outputs the
AND) of the signal "a" and safety signal "b", which is in-
put to Unit B.
Thereby the logic of the safety output "b" is output.)
To set the safety outputs of the subsequent Unit in the
ON state, its logical AND connection preset switch
must be set to AND (enable) and the high signal must
be input to T41 of the subsequent unit.
Cross fault
Y1
Selects the mode for the failure detecting (cross fault
detection input
detecting) function for the safety inputs of G9SX corre-
sponding to the connection of the cross fault detection
input.
Instantaneous
S14, S24 Turns ON/OFF according to the state of the safety in-
safety output
puts, feedback/reset inputs, and logical AND connec-
tion inputs.
During OFF-delay state, the Instantaneous safety out-
puts are not able to turn ON.
OFF-delayed
S44, S54 OFF-delayed safety outputs.
safety output
The OFF-delay time is set by the OFF-delay preset
switch.
When the delay time is set to zero, these outputs can
be used as non-delay outputs.
Logical AND
L1
Outputs a signal of the same logic and at the same time
connection output
as the instantaneous safety outputs.
Auxiliary monitor
X1
Outputs a signal of the same logic and at the same time
output
as the instantaneous safety outputs.
Auxiliary error
X2
Outputs when the error indicator is lit or flashing.
output
■ Connecting Safety Sensors
Safety sensors cannot be connected to safety inputs for the G9SX-NSA222-T03-@.
20
Compact Non-Contact Door Switch
Description of operation
D40A/
Flexible Safety Unit
Wiring
Connect the power supply minus (GND) to the A2 terminal.
Corresponds to Safety Catego-
ry 2
Corresponds to Safety Catego-
ry 3 (without short-circuit mon-
itoring between systems)
Corresponds to Safety Catego-
ry 3 (Cross fault detecting
mode (for safety inputs))
White
Black Brown
D1
D2
Auto reset
Manual reset
Input a
Unit A
G9SX-NS/NSA
L1 A2
Logical AND connection sig.
Output (a)
(1st layer)
Input b
Unit B
T41 T42
G9SX-NS/NSA
L1
A2
Logical AND connection sig.
Output (a&b)
(2nd layer)
T41 T42
G9SX-NS/NSA
L1
A2
Next unit (5 layers max.)
Keep Y1 open when using T11, T21. (Cross fault detecting mode
(for safety inputs))
Connect Y1 to 24 VDC when not using T11, T21. (Wiring
corresponding to category 2 or 3, or when connecting safety
sensors)
Keep these outputs open when not used.
Keep these outputs open when not used.
Keep these outputs open when not used.
Keep these outputs open when not used.
Keep these outputs open when not used.
G9SX-NS
+24 V
+24 V
T11 T12 T21 T22
Y1
+24 V
+24 V
+24 V
T11 T12 T21 T22
Y1
NC
T11 T12 T21 T22
Y1
Blue
D3
D4
Feedback loop
KM
+24 V
T31
T32
T33
Feedback loop
Reset
KM +24 V
Switch
T31
T32
T33
Next unit (4 unit max.)
T41 T42
G9SX-NS/NSA
Next unit (4 unit max.)