7. EXTERNAL WIRING

7.3.2 Example of connection with the MR-J A

Configure up a sequence to turn off
MC at alarm or emergency stop.
Power supply
3-phase 200VAC
A1FXCPU
Y axis
X axis
CW
B12
A12
COM
B11
A11
CCW
B14
A14
DC24
B15
A15
Zero speed detection
Analog torque limit command (+)
+10V/max. current
Monitor, max. 1mA meter
deflected one way
NF
Within 2m(6.65feet) *3
Servo-on
Reset
Torque limit
*1
Forward rotation stroke end
*1
Reverse rotation stroke end
RA1
Failure
RA2
A
Within 2m(6.56feet)
REMARKS
*1 Limit switch for servo (stop).
*2 For connection details, refer to the Specifications and Installation Guide of the
MR-J servo amplifier.
*3 Indicates a distance between A1FXCPU and amplifier.
Regenerative brake option
*2
N C P
MC
MR-J
A
R
S
T
CN1
SG
13
SG
16
SON
28
RES
29
TL
33
LSP
30
LSN
31
VIN
34
VDD
36
CN1
PP
20
SG
13
NP
22
VDD
36
CN1
VDD
36
ZSP
26
ALM
27
SG
16
CN1
P15R
1
TLA
3
LG
6
MO
4
LG
7
SD
18
7 - 6
MELSEC-A
Servo motor
U
U
V
V
W
W
E
CN2
Within 30m
(98.36feet)
SM