Battery/charging system with printer
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
2006/11/25 ◄ ► ↵
(Time Setting)
BRIGHTNESS
◄ ADJUST ►
BATTERY TYPE ◄ ► ↵
AGM FLAT PLATE
SELECT RATING ◄ ► ↵
SAE
SET CAPACITY ◄ ► ↵
×××× SAE
TESTING
IS BATTERY ◄ ► ↵
CHARGED? YES
14
Press ENTER to confirm time setting
Press ◄ / ► and adjust year setting.
Press Enter to get out of the year setting & to enter the month.
Proceed accoring to the previous instructions to complete the date, time &
minute settings.
Press Enter after adjusting the minute setting to start the battery test.
Press Enter to confirm brightness setting
Press ◄ / ► to adjust the brightness of the display.
Press Enter to confirm the brightness & go back to battery test.
Battery test (example)
Press the ◄ ► key to select battery test. Press Enter.
Press the ◄ ► key to select the battery type:
a) REGULAR LIQUID
b) AGM FLAT PLATE
c) AGM SPIRAL
d) VRLA/GEL
Confirm your selection with Enter.
Select the test standard SAE, EN, IEC, DIN or JIS with the ◄ ► keys.
Confirm with Enter.
Press the ◄ ► key to select the battery capacity in CCA
— SAE : 40~2000
— EN :
40~2100
— IEC :
30~1500
— DIN : 25~1300
— JIS :
By battery, type, no.
Press Enter to begin the test.
Test the battery for 5 -7 seconds.
Select one of the options with the ◄ ► key when the batteries are charged: Yes
or No
Confirm with Enter.
When the test is completed, the display shows the actual volts and the actual
CCA or %.
Press the ◄ ► key to select SOH (state of health) or SOC (state of charge). One
of six results will be displayed: