1.2 前視圖 C-6000FC/C-6000FCL C-6000F/C-6000FL/C-10000F/C-10000FL C-10000FC/C-10000FCL 3C-10000F/3C-10000FL/3C-20000FL 1.3 後視圖 ⑦ ⑦ ① ① ② ② ③ ③ ④ ④ ⑧ ⑧ ⑤ ⑤ ⑨ ⑨ ⑩ ⑩ ⑥ ⑥ C-6000FC/C-6000FCL C-10000FC/C-10000FCL/ C-6000F/C-6000FL C-10000F/C-10000FL...
Page 8
① ① ⑦ ② ③ ⑧ ④ ⑧ ⑦ ② ③ ⑤ ⑨ ⑨ ⑤ ⑩ ⑩ ⑥ ⑥ 3C-20000FL 3C-10000F/3C-10000FL ① 並機卡蓋板(並機卡為選配) ② EPO(緊急 POWER OFF) ③ RS232 ④ 電池連接插座 ⑤ 維護開關 ⑥ 束線架 ⑦ 智慧插槽 ⑧ 風扇 ⑨ 輸入開關 ⑩ 端子台蓋板...
2.2 配線表 注意:電纜的直徑和三根導線的橫截面積取決於UPS額定功率。 C-6000F/C-6000FL/ C-10000F/C-10000FL/ 型 號 C-6000FC/C-6000FCL C-10000FC/C-10000FCL 12AWG or 14 mm (硬線) 10AWG or 22 mm (硬線) 12AWG or 14 mm (硬線) 10AWG or 22 mm (硬線) 輸入 12AWG or 14 mm (硬線) 10AWG or 22 mm (硬線) 12AWG or 14 mm (硬線) 10AWG or 22 mm...
Page 48
UPS should be completely turned off, otherwise there might be a danger of electric shock because output terminal might be still electrified. 3. Please use EATON specified appendix devices and accessories. Battery Safety 1. Battery service lifetime will be shortened as ambient temperature rises.
Page 49
4. As accumulator batteries may contain potential electric shock and short- circuit current danger, to avoid accidents that might be thus resulted, the following warnings should be observed during battery replacement: A. Do not wear watches, rings or similar metallic items; B.
Page 50
C o n t e n t s C h a p t e r 1 B r i e f i n t r o d u c t i o n ..............1 1.1 Frequently used symbols....................1 1.2 Front view........................2 1.3 Rear view.........................2 1.4 Technical data........................4 C h a p t e r 2 I n s t a l l a t i o n ...................8...
UPS will transfer to bypass mode; if overload is removed, the UPS will transfer to inverter mode automatically. This manual is designed for On-Line series product as follows: • C-6000FC: the standard model with internal battery and LCD ;...
1.2 Front view C-6000FC/C-6000FCL C-6000F/C-6000FL/C-10000F/C-10000FL C-10000FC/C-10000FCL 3C-10000F/3C-10000FL/3C-20000FL 1.3 Rear view ⑦ ① ② ① ⑦ ③ ② ④ ③ ⑧ ④ ⑧ ⑤ ⑨ ⑤ ⑨ ⑩ ⑩ ⑥ ⑥ C-6000FC/C-6000FCL C-10000FC/C-10000FCL/ C-6000F/C-6000FL C-10000F/C-10000FL...
Page 53
① ⑦ ① ② ⑧ ③ ④ ⑦ ② ⑧ ③ ⑤ ⑨ ⑨ ⑤ ⑩ ⑩ ⑥ ⑥ 3C-20000FL 3C-10000F/3C-10000FL Parallel card (option) cover ① EPO (Emergency Power Off) ② RS232 ③ Battery connection socket ④ Maintenance switch ⑤ Cable clamp ⑥...
1.4 Technical data Model C-6000FC C-6000FCL C-6000F C-6000FL Dimensions 577× 290× 755 (W x D x H) (mm) Net Weight (Kg) Power Rating Apparent power (KVA)/ 6KVA/ Active power (KW) 4.8KW Input Voltage range 220VAC (-15%/+25%) Current* 33A.max 60Hz(+/-4Hz) Frequency range Power factor 0.99 Output...
Page 55
Model C-10000FC C-10000FCL C-10000F C-10000FL Dimensions 607× 300× 820 (W x D x H) (mm) Net Weight (Kg) Power Rating Apparent power (KVA)/ 10KVA/ Active power (KW) Input Voltage range 220VAC (-15%/+25%) Current* 55A.max 60Hz(+/-4Hz) Frequency range Power factor 0.99 Output 220(adjustable according to customer requirements) Voltage*...
Page 56
3C-10000F 3C-10000FL C-20000FL Model Dimensions (W x D x H) (mm) 607× 300× 820 607× 325× 936 Net Weight (Kg) Power Rating Apparent power (KVA)/Active 10kVA/ 20kVA/ power (KW) 16kW Input Voltage range 220VAC (-15%/+25%) 55A.max 110A.max Current* 60Hz(+/-4Hz) Frequency range 0.99 Power factor Output...
Page 57
*. The maximum current can be obtained when the UPS input is 187V, output is under rated full load, and charger works under full load. *. When output voltage is adjusted from 220V to 200V or 208V, the rated power of output VA and WATT should be decreased by 10%.
Ch a p t e r 2 I n s t a l la t i o n DANGER: Cut off the input switch, if it is the long back up time model, disconnect the battery input. CAUTION:1. The installation as described in this chapter may only be carried out by qualified technician, comply with the local electric law.
Model 3C-10000F/3C-10000FL 3C-20000FL 10AWG or 22 mm (hard wire) 8AWG or 30 mm (hard wire) Input 10AWG or 22 mm (hard wire) 6AWG or 38 mm (hard wire) 10AWG or 22 mm (hard wire) 6AWG or 38 mm (hard wire) 10AWG or 22 mm (hard wire) 6AWG or 38 mm...
Page 60
BAT+ BAT- BATTERY Fig. 1 6K/10K single phase input; single phase+2 wires, 220V output BAT+ BAT- BATTERY Fig. 2 6K/10K single phase input; single phase+2 wires, 110V output BAT+ BAT- BATTERY Fig. 3 6K/10K single phase input; single phase+3 wires, 220V/110V output Fig.
Page 61
Fig. 5 10K three phase input; single phase+2 wires, 110V output Fig. 6 10K three phase input; single phase+3 wires, 220V/110V output BAT+ BAT- BATTERY Fig. 7 20K three phase input; single phase+2 wires, 110V output...
BAT+ BAT- BATTERY Fig. 8 20K three phase input; single phase+2 wires, 220V output BAT+ BAT- BATTERY Fig. 9 20K three phase input; single phase+3 wires, 220V/110V output 2.4 Installation of external battery Perform the battery connecting procedure according to the following steps strictly: 1.
Page 63
UPS and battery configurations are as follows: Cabinet 12V, 7AH, 2 groups of 20 batteries C-6000FC 12V, 26AH, 1 group of 20 batteries C-6000FCL 12V, 40AH, 1 group of 20 batteries 12V, 7AH, 2 groups of 16 batteries C-6000F 12V, 26AH, 1 group of 16 batteries C-6000FL 12V, 40AH, 1 group of 16 batteries 12V, 7AH, 2 groups of 20 batteries...
B. Long backup time model with 1 external battery cabinet (1 group of 20 batteries, each of 12V, 26AH) Cabinet 2.5 Connecting to the Computer interface Computer interface: standard RS232 communication port, use a RS232 cable to connect the UPS with the monitor. 1.
2.6 Parallel operation (option) 1. Redundancy N+X is currently the most reliable structure in power protection. N represents the minimum number of the UPS blocks of the UPS system that the total load needs; X represents the number of the redundant UPS blocks of the UPS system, i.e. the number of the fault UPS block that the system can handle simultaneously.
Page 66
B). Connect each output wire to an output switchboard and then to the loads. Utility Input Switchboard Output Switchboard Load Load Load Load CAUTION: Requirement of output wiring length: When the lead from the output terminal of each set of UPS to the output patch board is less than 20m, wire difference should be less than 20%;...
Page 71
3). Single phase + 3 wires: 220V/110V input input input switch switch switch output output output switch switch switch battery 1 battery 2 battery 3 load utility 3. Advantages of parallel configuration This configuration improves the reliability of the power supply system through the redundancy frame structure.
3) Power off Select “LOAD OFF ALL” and confirm on the LCD of any set of UPS to shut down all the units; Select “LOAD OFF ALONE” and confirm on the LCD of any set of UPS to shut down one UPS alone.
2.8 EPO EPO (Emergency Power Off) is a green connector and located on the rear panel of the UPS. It can perform emergent power off when the UPS is under emergent condition. Two methods to carry out cable connection as followed. ①...
2.9 Maintenance switch There are voltages present inside the UPS when it works under line mode, battery mode or bypass mode, so you can make the UPS separate with the utility via closing the Maintenance switch and thus ensure safe on-line maintenance. Maintenance switch Battery Maintenance switch...
C h a p t e r 3 L C D O p e r a t i o n 3.1 Control Panel It is applicable for the following models: C-6000FC: the standard model with internal battery and LCD ; C-6000FCL: the long back up time model with external battery and LCD ;...
3.2 Start up Prior to UPS startup, make sure the cables and terminal blocks are connected properly, otherwise, electric shock may occur. 2 . T h e f o l l o w i n g s c r e e n a p p e a r s 1.
3.3 Shut down 1. Switch-off screen (1) 2. Switch-off screen (2) (selftest is enabled) COMMAND COMMAND SELFTEST HELP HELP 3. If it is in single machine mode (default), the following screen will appear, then press Enter to confirm. CONFIRM LOAD OFF ALONE NO, CANCEL YES, CONFIRM In parallel mode, you can select to load off single UPS alone or load off all units.
Shut down in ECO mode 1. Switch-off screen (selftest is disabled) 2. Press Enter and the following screen will appear. COMMAND SELECT COMMAND LOAD OFF ALONE ECO DISABLE HELP 3. Select "LOAD OFF ALONE" and press 4. Select "ECO DISABLE" and press Enter, the following screen will appear.
3. Press again to obtain the below 4. Press again to obtain the below information. information. INPUT PARAMETER BYPASS PARAMETER VIN: 220.5V VIN: 220.5V FREQ: 60.0Hz VFREQ: 60.0Hz 5. Press again to obtain the below 6. Press again to obtain the below information.
3.6 Help 1. Select "Help" and press Enter. 2. Select the following items and press Enter to obtain the information of service hotline, run record or inverter temperature. HELP COMMAND SERVICE CONFIGURATION RUN RECORD HELP OTHERS 3.7 Self test 1. The following screen can be obainted 2.
Page 81
Submenu Item list Instruction SERVICE To inquiry the service hotline HELP SERVICE 1. Current fault; 2. history record 3. RUN RECORD RECORD clear record OTHERS OTHERS To inquiry the temperature of inverter 1. Load Fail-Safe Defaults; 2. the testing time can be set from 1 to 99, TEST and the default value is 1min;...
3.8 Display reference table Indicator Working BUZZER LCD display Inverter Battery Bypass Fault condition Line mode Normal ● none Battery not connected/Charger one beep every 1 fault/Fan fault/LN connection Alarm ● ④ ★ second reversed or E not connected/ Bypass fault Battery one beep every 1...
Chapter 4 LED Operation 4.1 Control panel It is applicable for the following models: C-6000F: the standard model with internal battery and LED; C-6000FL: the long back up time model with external battery and LED; C-10000F: the standard model with internal battery and LED; C-10000FL: the long back up time model with external battery and LED;...
Page 84
11#~12# Load/Battery capacity icons: 11# Load capacity icon: the load capacity increases by degrees as the indicators are lit one by one from 6# to 2#. 12# Battery capacity icon: the battery capacity increases by degrees as the indicators are lit one by one from 2# to 6#.
4.2 Start up Note: the battery is fully charged before delivery. However, storage and transportation will inevitably cause some charge loss. Therefore, it is advisable to charge the battery for 12 hours before using it, so as to ensure adequate battery autonomy. Indicator:...
• The battery LED indicators are turned on and the line LED is turned off. Battery supplies power to the load. (Battery mode) • In battery mode, the buzzer beeps once every 4 seconds, press the function button more than 2 seconds to silence the audible alarm. 4.3 Shut down •...
4.4 Maintenance If fault LED is lit or buzzer beeps, it indicates UPS fault or alarm . Problem Possible cause Solution Ensure that the UPS is not overloaded, the ventilation opening The 1# and 6# LEDs are lit, the UPS internal temperature is not blocked and ambient temperature is not too high.
Chapter 5 Battery Maintenance The battery is key component of the UPS. The battery life depends on the ambient temperature, charge and discharge times. High ambient temperature and deep discharge will shorten the battery life. Sealed maintenance-free lead acid batteries are used in the UPS. Before electricity is switched on, make sure earthing is properly done and wire and battery polarity are correctly connected.
Appendix 1 One year warranty This Warranty Card warrants the Product against defects in materials and workman- ship under normal use for a period of one year from the date of purchase by the original end-user purchaser. During the warranty period, should the Product fail due to improper workmanship or materials, our company will repair the Product at free of charge.
Page 92
SOLE LIMIABLE AND PURCHASER’S EXCLUSIVE REMEDY FOR THE PRODUCT. THERE IS NO OTHER WARRANTIES, IMPLIED OR STATUTORY WARRANTIES OTHER THAN THIS WARRANTY CARD. SERIAL NO. The distributor stamps User Name Telephone The date of purchase Manufacturer: Eaton Phoenixtec MMPL CO.,LTD. Made in Taiwan...