Operating manual
Operating manual ..................................................page 1 - 44
Temperature Calibrators
Series TP 17 / TP M / TP Multi
Please keep this operating manual for future reference.
If the device is resold, please provide the operating manual along with it.
SIKA Dr.Siebert & Kühn GmbH & Co.KG  Struthweg 7–9  D-34260 Kaufungen  Germany
 +49 5605 803-0   +49 5605 803-54  info@sika.net  www.SIKA.net
(Translation)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP 17 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIKA TP 17 Series

  • Page 1 If the device is resold, please provide the operating manual along with it. SIKA Dr.Siebert & Kühn GmbH & Co.KG  Struthweg 7–9  D-34260 Kaufungen  Germany  +49 5605 803-0   +49 5605 803-54  info@sika.net  www.SIKA.net...
  • Page 2: Table Of Contents

    14.2 Characteristics series TP 17 …................36 14.3 Characteristics series TP 17 … S ................. 37 14.4 Characteristics series TP M … S ................38 14.5 Heating and cooling periods.................. 39 - 2 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 3: About This Operating Manual

    Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 • D - 34260 Kaufungen  05605-803 0 •  05605-803 54 info@sika.net • www.sika.net Hazard signs and other symbols used: CAUTION! Electric current! This sign indicates dangers which could arise from handling of electric current.
  • Page 4: Description Of The Device

    The calibrator / micro calibration bath is a portable unit for service, industry and laboratory tasks. The SIKA temperature calibrators / micro calibration baths are intended to calibrate thermometers, temperature switches/thermostats, resistance thermometers and thermal ele- ments.
  • Page 5: Intended Use

    TP 17 / TP M / TP Multi Description of the device Scope of delivery and accessories: Before installing the device, check the delivered items and ordered accessories: Temperature calibrator and accessories (included items): Metal block calibrator: Micro calibration bath: ...
  • Page 6: Exclusion Of Liability

    However, professional and safety conscious conduct of the operator is required to ensure safe operation SIKA provides support for the use of its products either personally or via relevant literature. The customer verifies that our product is fit for purpose based on our technical information.
  • Page 7: Safety Instructions For The Application Of Calibration Liquids

    Once the metal bock / liquid bath has cooled down, the calibrator / micro calibration bath has to be returned to SIKA for inspection. The calibrator / micro calibration bath has been designed as a measurement and control instrument.
  • Page 8: Construction

    The 5-pole socket is provided for service purposes and is additionally used as a data inter- face to the PC for the S version. - 8 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 9: Front Of The Controller (Controller Type K32Sk)

    TP 17 / TP M / TP Multi Construction 3.1 Front of the controller (controller type K32SK) Overview and function of the control elements of the controller: 6 -  key  - Increasing the setting values.  - Selecting individual menu items. ...
  • Page 10: Transmission Protocol (S Versions)

    If you access the programming via the keypad while communication via a serial interface is running, the message "buSy" appears on the display. 3.3 Transmission protocol (S versions) Only applies for the S version and is supplied as an additional document on request. - 10 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 11: Using Test Specimen Fixtures

    TP 17 / TP M / TP Multi Using Test Specimen Fixtures Using Test Specimen Fixtures The temperature calibrators in the TP 17 / TP M / TP Multi series can be used with various test device fixtures, depending on the model. Configuration as a metal block calibrator, infrared calibrator, calibrator for surface sensors or micro calibration bath is easily performed with minimal effort.
  • Page 12: Calibrator For Surface Sensors

    - 12 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 13: Micro Calibration Bath

    TP 17 / TP M / TP Multi Using Test Specimen Fixtures 4.4 Micro calibration bath ATTENTION! Safety valve! The transport cover is equipped with a safety valve, which is activated once the pressure reaches approx. 2.5 bar. This can result in hot steam being released. ...
  • Page 14 Rise due to stirring The rotation of the magnetic stirrer forms a whirlpool in the liquid. This raises the fill level at the wall. Maximum fill level of the liquid bath - 14 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 15 TP 17 / TP M / TP Multi Using Test Specimen Fixtures Tank: The max. filling level in the tank is displayed by the upper edge of the aluminium lining. The max. filling level is ~0,45 litres. Tub insert: The maximum fill level with the tub insert is below the fixture for the sleeve changing tool. The maximum filling amount is approximately 0.32 litres.
  • Page 16: Commissioning

    I. The start-up set point is T =120°C for a stop period of t =15 min. start - 16 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 17: Switching On The Calibrator / Micro Calibration Bath

    TP 17 / TP M / TP Multi Commissioning 5.2 Switching on the calibrator / micro calibration bath  Connect the supplied mains plug to a mains outlet.  Actuate the mains switch.  The controller is initialized.  tESt appears on the upper display. ...
  • Page 18: Testing Temperature Sensors

    Reference. CAUTION! Incorrect results! It is not possible to calibrate earthed thermal elements, because the heating block is earthed and any measurement would produce incorrect results. - 18 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 19: Operating The Calibrator / Micro Calibration Bath

    TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath Operating the Calibrator / Micro Calibration Bath Three operating modes are available: Calibration mode: This is the normal operating mode in which the calibration of test specimens is carried out. Set point mode: The set temperatures can be entered in this mode.
  • Page 20: Setting A Temporary Set Temperature (Set Point Mode)

     If no key is pressed in the set point mode for approx. 15 seconds, the device auto- matically returns to the calibration mode. - 20 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 21: Main Menu

    TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath 7.3 Main menu All the settings can be carried out in this menu structure.  Press the P key for approx. 5 seconds. The main menu opens. ...
  • Page 22 If no key is pressed in the main menu at the group or parameter level for approx. 15 sec- onds, the device automatically returns to the previous level up to the calibration mode. You can also return to a previous level by pressing and holding the   key. - 22 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 23 TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath 7.3.1 Automatic control For certain tasks it can be advantageous to switch off the control, e.g. to carry out settings at the calibrator / micro calibration bath. Switching off automatic control: ...
  • Page 24 LED SET flashes on the lower display.  Confirm switching on the automatic controller by pressing the arrow key until the desired operating mode is displayed and confirm this with the P key. OPLO display - 24 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 25 TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath 7.3.3 Fixed set temperatures (S version) Setting and saving fixed set temperatures (S version) In order to save set temperatures in the calibrator / micro calibration bath, the respective set point memory has to be opened ...
  • Page 26 SP1 has been achieved and after a programmed duration time “dur.t”; this creates a simple temperature profile. After switching on the calibrator / micro calibration bath the temperature profile is automati- cally carried out. Gradient control and temperature profile - 26 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 27 TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath Setting values for „SLor“ and „SLoF“ Calibrator type Heating gradient Cooling gradient „SLor“ „SLoF“ Heating/Cooling: < 7 °C/min < 5 °C/min TP 17 165 S TP M 165 S / TP 17 166 /TP 17 200 <...
  • Page 28 rEG appears on the lower display and LED SET flashes. Group rEG  Press the P key again, the parameter level opens. rEG appears on the upper display. SLor flashes on the lower display Parameters for heating gradient SLor - 28 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 29 TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath 7.3.4.1 Setting the heating gradient (S version) The heating gradient "SLor" is active if the reference temperature is lower than the set tem- perature. The setting range extends from 99.99 °C/min up to 0.00 °C/min. PLEASE NOTE: The function is deactivated if SLor = InF (In no Function) has been set.
  • Page 30 After carrying out the settings, the calibrator / micro calibration bath uses the new values only when modifying the set temperature or switching the calibrator / micro calibration bath off and on again. - 30 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 31 TP 17 / TP M / TP Multi Operating the Calibrator / Micro Calibration Bath 7.3.4.3 Setting the duration time (S version) The duration time "dur.t" is active if the set temperature SP1 has been achieved. Subse- quently, the calibrator / micro calibration bath automatically switches to set temperature SP2. The setting range extends from 99:59 [hh:min] to 00:00 [hh:min].
  • Page 32: Cooling Down Of The Metal Block / Liquid Bath

    Each calibrator is fitted with a small meshed air grille via which cooling air enters the calibra- tor.  Clean the grille at regular intervals (vacuuming or brushing) depending on the level of air pollution. - 32 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 33: Problems

    TP 17 / TP M / TP Multi Problems Cleaning calibrators with sleeves: A small amount of brass dust is created when operating calibrators with sleeves, this can cause the metal block and sleeve to jam.  To prevent this, remove the sleeves from the heating block at regular intervals and if the calibrator is not going to be operated for a longer period.
  • Page 34: Warranty And Repairs

    DIN ISO 10 012. We recommend you to re- turn the calibrator / micro calibration bath to SIKA at intervals of max. 12 months or approx. 500 operating hours for recalibration and readjustment.
  • Page 35: Technical Data

     Take the TP 17 / TP M / TP Multi to your lo- cal recycling plant  send the TP 17 / TP M / TP Multi back to your supplier or to SIKA. 14 Technical data The technical data of customised versions may differ from the data in these instructions.
  • Page 36: Characteristics Series Tp 17

    ~300 mm ~269 mm Weight ~11,4 kg ~12,1 kg ~14,6 kg ~7,5 kg Sleeves for smaller  1,5…25 mm 1,5…55 mm 1,5…25 mm 1,5…55 mm 1,5…25 mm (in 0,5 mm steps) - 36 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 37: Characteristics Series Tp 17

    TP 17 / TP M / TP Multi Technical data 14.3 Characteristics series TP 17 … S Series Characteristics 17 165 S 17 166 S 17 200 S 17 450 S 17 650 S Calibrator Display range: -50…165 °C -50…165 °C -60…200 °C 0…450 °C 0…650 °C Setting range: - Dry block...
  • Page 38: Characteristics Series Tp M

    ~147 mm - Height ~380+50 mm ~330+68 mm ~330+68 mm - Depth ~300 mm ~269 mm ~269 mm Weight ~13,0 kg ~7,5 kg ~7,5 kg Sensor basket working depth 150 mm - 38 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 39: Heating And Cooling Periods

    TP 17 / TP M / TP Multi Technical data 14.5 Heating and cooling periods The following measurement conditions apply to heating and cooling times:  All times are elapsed times without settling time.  The measurements were carried out at a room temperature of approx. 23 °C ...
  • Page 40 Technical data TP 17 / TP M / TP Multi 14.5.2 TP 17 450; TP 17 650 (dry block) 14.5.3 TP 17 166 S; TP 17 450 S (infrared, surface) - 40 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 41 TP 17 / TP M / TP Multi Technical data 14.5.4 TP M 165 S Dry block, infrared and surface Water and silicone oil Technical changes reserved - 41 -...
  • Page 42 Technical data TP 17 / TP M / TP Multi 14.5.5 TP M 225 S, TP M 255 S Dry block, infrared and surface Water and silicone oil - 42 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...
  • Page 43 TP 17 / TP M / TP Multi Technical changes reserved - 43 -...
  • Page 44 TP 17 / TP M / TP Multi - 44 - © SIKA • Ba_TP17-TPM-Multi_en.doc • 01/2014...

Table of Contents