Page 2
Betriebsanleitung ............Seite 1 - 24 Operating manual ..........page 25 - 48 Digital pressure gauges Reference type E2 / D2 Please keep this operating manual for future reference. If the device is resold, please provide the operating manual along with it.
E2 / D2 About this operating manual About this operating manual The operating manual is aimed at specialists and semi-skilled personnel. Before each step, read through the relevant advice carefully and keep to the specified order. Thoroughly read and understand the information in the section "Safety instructions".
The references have accuracies of ±0.5 % Type E2 and ±0.1 % Type D2, relative to the corre- sponding full-scale reading (FS). Used as a pressure reference, they provide an easy way of checking, adjusting and calibrating other items of pressure measuring equipment.
The digital manometer E2 / D2 is intended solely for inspecting, adjusting and calibrating pressure measuring equipment. Do not use the reference E2 / D2 outside the specifications and do not disregard the operat- ing instructions. WARNING! No safety component! the reference E2 / D2 is not a safety component in accordance with Directive 2006-42-EC (Machine Directive)..
( § 9 "Technical data"). Only use the E2 / D2 if it is in perfect condition. Damaged or faulty devices must be checked without delay and, if necessary, replaced. When fitting, connecting and removing the E2 / D2 use only suitable appropriate tools.
Unit display. Status line. The digital pressure gauge E2 / D2 has a LCD display with additional elements and a graphic bar graph display. The measured values are displayed as numbers in the 4 ½ -digit display . The selected...
Page 9
That is ensured with the P40.2 pneumatic hand pump. The E2 / D2 reference is screwed via the pres- sure connection shanks directly to the hand pump.
Connection and battery replacement Connection and battery replacement The digital manometer E2 / D2 has a G¼" (BSPP) male thread and is supplied with batteries fitted. The device is ready for operation after it is switched on ( § 5.2).
E2 / D2 4.2 Battery replacement The battery capacity is continuously monitored by the electronics of the E2 / D2 and is indicated by the number of bars (0…5 bars) in the battery symbol. The batteries should be replaced when no bar is visible and the battery symbol flashes.
E2 / D2 Commissioning, switching on and off Commissioning, switching on and off The digital manometer E2 / D2 is supplied with batteries fitted. The device is ready for opera- tion after it is switched on ( § 5.2). 5.1 Commissioning Before switching on the E2 / D2 for first time and when making changes in the measurement setup, follow the instructions below.
Measuring mode and operation of the Functions E2 / D2 Measuring mode and operation of the Functions After switching on and completion of the start-up procedure, the E2 / D2 enters measuring mode. The current reading is displayed. 6.1 Measuring mode...
E2 / D2 Measuring mode and operation of the Functions 6.1.1 Menu for device settings The device functions "Automatic shut-off", "Units" and "Display filter" are configured in the menu for device settings. The following illustration shows the procedure for creating the device settings: Call the device settings menu with the MENU button.
The " " display appears when the current pressure lies outside of the pressure range ( 110% FS) of the E2 / D2. If the pressure falls be- low that, the current measurement value is displayed. The MAX value continues to display "...
Page 16
E2 / D2 Measuring mode and operation of the Functions Zero point correction (ZERO) If there are undesired deviations in the pressure less state (atmospheric pressure), the zero point can be manually corrected. CAUTION! Faulty measurements! The zero point correction sets the current ACTUAL value to zero. If the ZERO function is activated when pressure is applied, the pressure measurement is no longer made against the ambient pressure, resulting in faulty measurements.
If the function is deactivated, the device is in continuous duty and has to be manually switched off with the ON/OFF button. The current setting is displayed when the device E2 / D2 is switched on: " " = activated (automatic shut-off);...
Page 18
E2 / D2 Measuring mode and operation of the Functions Filter setting (damping): The menu item " " is used to dampen the display. Keep pressing the MENU button until the menu item " " appears. " " appears and right of it the current value ( ).
1.5 years ( "replacing the batteries"). Cleaning: Clean the E2 / D2 with a dry or slightly damp lint-free cloth. Do not use sharp objects or ag- gressive agents for cleaning. Storage, transport: PROCEED CAUTIOUSLY! Electronic Component! The device contains sensitive electronic components.
Observe the legal regulations of the country in which the device is marketed. NO HOUSEHOLD WASTE! The E2 / D2 consists of various different materials. It must not be disposed of with household waste. Take the E2 / D2 to your local recycling plant send the E2 / D2 back to your supplier or to SIKA.
E2 / D2 Technical data The technical data of customised versions may differ from the data in these instructions. Please observe the informations specified on the type plate. Characteristics Reference E2 / D2 Measuring ranges input Piezzo resistive pressure cell -1…3 bar DMS pressure cell -1…40/60 bar and 0…400/700/1000 bar...
Page 22
E2 / D2 Technical data Display resolution Measuring mH2O mbar range (kg/cm2) -1…3 bar -.999….3.000 -10.2…30.6 -15.0…45.0 -999…3000 -100.0…300.0 -1…40 bar -1.00….40.00 -10.2…408.2 -15…580 -100…4000 -0.10…4.00 -1…60 bar -1.00….60.00 -10.2…612.2 -15…870 -100…6000 -0.01…6.00 0…400 bar 0.0…..400.0 0…4082 0…5800 0…4000(x10) 0.00…40.00 0…700 bar...