Series TP 17...M
Types TP 17165M • TP 17650M
Please keep this operating manual for future reference.
If the device is resold, please provide the operating manual along with it.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP 17165M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIKA TP 17165M

  • Page 1 Temperature Calibrators Series TP 17...M Types TP 17165M • TP 17650M Please keep this operating manual for future reference. If the device is resold, please provide the operating manual along with it.
  • Page 2: Table Of Contents

    Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. - 2 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 3: About This Operating Manual

    Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 • D - 34260 Kaufungen  +49 5605 803-0 •  +49 5605 803-555 info@sika.net • www.sika.net Hazard signs and other symbols used: CAUTION! Electric current! This sign indicates dangers which could arise from handling of electric current.
  • Page 4: Device Description

     Check the completeness of the delivery based on the delivery note. Save the packaging! Temperature calibrators are delivered in special protective packaging.  Save the packaging for returning the instrument safely to the manufacturer for recal- ibration or repair. - 4 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 5: Intended Use

    TP 17...M Device description Scope of delivery and accessories: Scope of delivery: Accessories (optional):  Metal block calibrator according to order  Transport case. data.  Transport bag (only TP 17650M).  Mains cable.  Adapter sleeves.  Sleeve exchange tools. ...
  • Page 6: Warranty

    In order to guarantee that the device operates safely, the operator must act competently and be conscious of safety issues. SIKA provides support for the use of its products either personally or via relevant literature. The customer verifies that our product is fit for purpose based on our technical information.
  • Page 7 The calibrator cannot then be started any more.  After it has cooled, send the calibrator for inspection to SIKA. The calibrator may not be used in an explosion-endangered atmosphere (ignitable or ex- plosive atmosphere).
  • Page 8: Construction And Function

    The calibrator heats or cools the metal block to the set temperature. As soon as this temper- ature has been reached and is stable, the calibration of the test specimen can be carried out. Then, the next test point is approached or the testing procedure is ended. - 8 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 9: Commissioning And Operation

    TP 17...M Commissioning and operation Commissioning and operation CAUTION! Risk of injury or material damage! The calibrator can become very hot during operation. If the machine is operated without supervision, third-party persons in the vicinity could get injured. Moreover, flammable material could get into the machine and cause significant damage to property.
  • Page 10: Electrical Connection

    IMPORTANT! Mains connecting cable! The mains connecting cable may only be replaced by an equivalent cable.  Use only original cables from SIKA or approved cables of the same type with the cor- rect design as replacements ( § 10.1 "Electrical characteristics").
  • Page 11: Preparation Of The Calibrator

    Inserting: Only use the supplied adapter sleeves made of the appropriate material. If in doubt, contact SIKA for clarification.  The appropriate adapter sleeve is inserted into the metal block with the aid of the sleeve exchange tool.
  • Page 12: Switching On, Cool Down And Switching Off

    2 indicates the status of the output for the active cooling. If the LED OUT 2 lights up, the ac- tive cooling is running. If the LED OUT 2 does not light up, the cooling is not active. - 12 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 13: Operating Modes

    TP 17...M Commissioning and operation IMPORTANT! Mains failure or separation from the mains! If there is a mains failure, or if the main switch is turned off, or upon removal of the mains connection ("EMERGENCY STOP"), the built-in fan does not blow any more cooling air.
  • Page 14: Operation

    ☼ If LED OUT 2 is lit, the calibrator is cooling. • Reducing values to be set.  If LED OUT 2 is not lit, the calibrator is not cooling. • Display of operating hours. - 14 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 15: Calibration (Calibration Mode)

    TP 17...M Operation 5.2 Calibration (calibration mode) As soon as the calibrator has been switched on, it switches to the calibration mode after ini- tialization. 5.2.1 Display of reference and set temperature The current reference temperature is displayed in the upper and the set temperature in the lower of the display.
  • Page 16 If the LED OUT 2 is not lit the fan is running at low speed. Fan / cooling control active b) Heating and cooling instrument (TP 17165M) The LED OUT 2 indicates the status of the output for the cooling control: •...
  • Page 17: Set A Set Temperature (Set Point Mode)

    TP 17...M Operation 5.3 Set a set temperature (set point mode) In this operating mode it is possible to modify a saved set temperature.  Press the P key shortly. The currently active set point memory, e.g. SP 1 (set point 1), is displayed by the upper display.
  • Page 18: Testing Process / Calibration

     the correct measuring insert has been selected for the testing process ( § 4.3).  the test specimen is securely fixed in the calibrator.  the calibrator has sufficient structural stability. - 18 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 19 TP 17...M Testing process / Calibration Performing testing process: During the testing process, one or more test points are approached and the reference tem- perature of the calibrator is compared with the measured temperature of the specimen.  Set the set temperature to the value of the first test point. ...
  • Page 20: Troubleshooting

    Contact your supplier or directly SIKA. Please send the device for repair with a brief descrip- tion of the problem, the environmental conditions and the length of time the device was oper- ational before the problem occurred.
  • Page 21: Return Shipment To The Manufacturer

    TP 17...M Troubleshooting 7.1 Return shipment to the manufacturer  Please follow the instructions on the return of goods on our website (www.sika.net/en/services/return-of-products-rma.html). Technical changes reserved - 21 -...
  • Page 22: Maintenance, Cleaning And Transport

     Fit the fuse compartment back in place and connect the mains connecting cable ( § 4.2 "Electrical connection"). Should the fuses blow repeatedly, there is probably a fault in the calibrator. In this case, send the calibrator to SIKA for repairs ( § 7+§ 7.1). - 22 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 23: Cleaning

    The calibrator should, depending on the application situation, be inspected at appropriate in- tervals on the basis of DIN ISO 10012. We recommend you to return the calibrator to SIKA at intervals of max. 36 months or approx. 500 operating hours for recalibration and readjust- ment.
  • Page 24: Decommissioning And Disposal

    The calibrator of the series TP 17...M consists of various different materials. It must not be disposed of with household waste.  Take the TP 17...M to your local recycling plant  send the TP 17...M back to your supplier or to SIKA. * WEEE reg. no.: DE 25976360 - 24 -...
  • Page 25: Technical Data

    10 Technical Data The technical data of customised versions may differ from the data in these instructions. Please observe the information specified on the type plate. 10.1 Characteristics series TP 17…M Series TP 17165M TP 17650M Characteristics Kalibrator Temperature range -35…165 °C...
  • Page 26 0…50 °C Transport and storage tempera- -10...60 °C ture Humidity (RH) 30…95 % (non-condensing environment) Operating conditions: - Location • Altitude Interiors • up to 2000 m - Operating position Standing upright/vertically - 26 - © SIKA • Ba_TP17M_en • 03/2019...
  • Page 27: Heating And Cooling Periods

    TP 17...M Technical Data 10.2 Heating and cooling periods The heating up and cooling times are dependent on the parameters of the test task used and the ambient conditions. The following times are guide values for a room temperature of 23 °C without settling processes.