8.1 General Specifications

Mains supply 200-240 V AC - Normal overload 110% for 1 minute
Frequency converter
Typical Shaft Output [kW]
IP20/Chassis
(A2+A3 may be converted to IP21 using a conversion kit. (See
also Mechanical mounting and IP21/Type 1 Enclosure kit in the
Design Guide.))
IP55/Type 12
IP66/NEMA 4X
Typical Shaft Output [HP] at 208 V
Output current
Continuous
(3x200-240 V) [A]
Intermittent
(3x200-240 V) [A]
Continuous
kVA (208 V AC) [kVA]
Max. input current
Continuous
(3x200-240 V) [A]
Intermittent
(3x200-240 V) [A]
Additional specifications
Estimated power loss
at rated max. load [W]
IP20, IP21 max. cable cross
section (mains, motor, brake and
load sharing) [mm
IP55, IP66 max. cable cross
section (mains, motor, brake and
load sharing) [mm
Max. cable cross section with
disconnect
Weight enclosure IP20 [kg]
Weight enclosure IP21 [kg]
Weight enclosure IP55 [kg]
(A4/A5)
Weight enclosure IP66 [kg]
(A4/A5)
Efficiency
Table 8.1 Mains Supply 200-240 V AC
®
VLT
Refrigeration Drive Design Guide
P1K1
1.1
A2
A4/A5
A4/A5
1.5
6.6
7.3
2.38
5.9
6.5
63
4)
2
(AWG)]
2
(AWG)]
4.9
5.5
9.7/13.5
9.7/13.5
3)
0.96
®
MG16G102 - VLT
is a registered Danfoss trademark
P1K5
P2K2
P3K0
1.5
2.2
A2
A2
A3
A4/A5
A4/A5
A5
A4/A5
A4/A5
A5
2.0
2.9
4.0
7.5
10.6
12.5
8.3
11.7
13.8
2.70
3.82
4.50
6.8
9.5
11.3
7.5
10.5
12.4
82
116
155
4, 4, 4 (12, 12, 12)
(min. 0.2 (24))
4, 4, 4 (12, 12, 12)
6, 4, 4 (10, 12, 12)
4.9
4.9
6.6
5.5
5.5
7.5
9.7/13.5
9.7/13.5
13.5
9.7/13.5
9.7/13.5
13.5
0.96
0.96
0.96
P3K7
3
3.7
A3
A5
A5
4.9
16.7
18.4
8
6.00
15.0
16.5
185
6.6
7.5
13.5
13.5
0.96
105