Wayne 320702-001 Operating Instructions And Parts Manual

Submersible utility pump
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Operating Instruction and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
This portable, submersible utility pump
is designed for non-automatic use in
water. The unit is equipped with a 10
ft. 3-prong grounding type power cord.
The pump's outlet fitting is designed
for convenient discharge through a
garden hose. This pump is not
designed for ponds or fountains.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Very Important Safety
Information
Always follow these safety guidelines
to avoid bodily injury or property
damage.
Do not
use to
pump flammable or
explosive fluids such as
gasoline, fuel oil, kerosene,
etc. Do not use in flammable and/or
explosive atmospheres. Pump should be
used only to pump clear water. Personal
injury and/or property damage could
result.
Risk of
electric
shock! This pump has not
been investigated for use
in swimming pool areas.
Never place pump in pool while people
are in the water.
Do not handle
pump with wet
hands or when standing in water or on
a damp surface.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2004 Wayne Water Systems
Submersible
Utility Pump
1. Wear safety glasses at
all times when working
with pumps.
2. It is strongly
recommended that this unit is
plugged into a Ground Fault Circuit
Interrupter (GFCI) (See
Figure 1). Consult a local electrician
for installation and availability.
Grounding
blade
Figure 1
3. Do not use the power cord or
discharge hose to carry or hang the
pump, always use the handle.
Installation
Always disconnect
the electric supply
before attempting to install, service,
relocate or perform any maintenance. If
the power source is out of sight, lock
and tag in open (off) position to
prevent unexpected power application.
Failure to do so could result in fatal
electrical shock.
Important: This unit is not designed
for use in septic tanks or underground
vaults to pump raw sewage or
effluents. Never use in hazardous or
explosive locations.
1. This pump has been designed to
attach to a standard garden hose.
Thread the female end of the
garden hose to the male discharge
on the pump (see Figure 2) .
For parts, product & service information
visit www.waynepumps.com
1
GFU Series
Female
end of
garden
hose
Figure 2
2. To reduce leakage between the
pump and the hose, place a hose
washer (not included) on the hose
fitting prior to installing the hose to
the pump (see Figure 3).
Hose Washer
(not included)
Figure 3
3. For best performance, unwind hose
before starting the pump. Remove
kinks or bends in the hose to allow
unit to pump unrestricted (see
Figure 4).
Figure 4
320702-001 3/04
Correct
Incorrect

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 320702-001

  • Page 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2004 Wayne Water Systems Submersible Utility Pump 1. Wear safety glasses at all times when working with pumps.
  • Page 2: Installation

    Operating Instructions And Parts Manual Installation (Continued) 4. Do not set the pump directly on dirt, mud or sand. This will cause the inlet to clog. Set pump on a hard surface in water. Operation Do not touch pump, pump motor, water or discharge piping when the pump is connected to electrical power.
  • Page 3 Ne MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2004 Wayne Water Systems Pompe Immergée Tout Usage jamais placer la pompe dans une piscine s’il y a des personnes dans...
  • Page 4: Entretien

    Instructions D’Utilisation Et Manuel De Pièces Installation (Continued) Correct Incorrect Figure 4 4. Ne pas positionner la pompe directement sur le sol, la boue ou le sable. Ceci peut causer une obstruction dans l’arrivée. Placer la pompe sur une surface solide dans l’eau.
  • Page 5: Instalación

    Jamás introduzca la bomba en una piscina cuando haya gente en el RECORDATORIO: ¡Guarde su prueba de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. © 2004 Wayne Water Systems Bomba Sumergible de Uso General agua.
  • Page 6: Mantenimiento

    Manual de Instrucciones de Operación y Partes Instalación (Continuación) Correcto Incorrecto Figura 4 4. No coloque la bomba directamente sobre tierra, barro o arena, pues esto hará que la entrada de la bomba se atore. Ponga la bomba sobre una superficie dura en el agua.
  • Page 7 Operating Instructions And Parts Manual Instructions D’Utilisation Et Manuel De Pièces Manual de Instrucciones de Operación y Partes Notes Notes Notas www.waynepumps.com...
  • Page 8: Limited Warranty

    Limited Warranty For one year from the date of purchase, Wayne Water Systems (“Wayne”) will repair or re place, at its option, for the original purchaser any part or parts of its Pond Kit, Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or work man ship. Please call Wayne (800-237-0987) for instructions or see your dealer.

This manual is also suitable for:

Gfu series

Table of Contents