Making the Initial Electrical Connections
REVERSE POLARITY / MISWIRING: Reverse polarity or incorrect voltage
may damage the light. To avoid damage to the light, ensure that the battery
voltage is the same as the voltage rating of the light and that the correct
polarity is observed. If you are connecting to a cigarette lighter plug or 12 V
outlet, connect the positive wire to the center terminal and connect the
negative wire to the outer terminal.
The Legend does not require any internal wiring. Two 10 AWG power conductors
(red and black) and a CAT5 cable exit the light bar. The light bar's basic light
functions are communicated through the CAT5 cable, which connects to the Serial
Interface Module. (The Discrete-Wired 24-inch Legend does not connect to the
Serial Interface Module and has no CAT5 cable.) For wiring schematics, see the
Appendix starting on page 52.
To make the electrical connections for reprogramming the light bar:
1. To supply power to the light bar, use a fully-charged 12-volt automotive battery
with terminal lugs.
2. Place the light bar on a sturdy, flat surface.
3. Plug the CAT5 communication cable (1) from the light bar into the Serial Interface
Module (J1). See Figure 1.

Figure 1 Electrical connections for testing and reprogramming

Driver
Side
5
+
Fuse
Installation, Operation, and Service Manual
Federal Signal www.fedsig.com
45-inch Legend (LGD45)
Fuse
40 A Maxi
4
3
Ground Power Line (Black)
6
12 Vdc
Vehicle
Battery
Black Wire
Black / White Wire
1 A
White Wire
Preparing the Legend for Installation
Power Line (Red)
Serial
Interface
Module
2
24-Pin Harness
Passenger
Side
CAT5
Com.
Cable
(Gray)
1
290A5957B