Overview of the Legend Light Bar
Follow the standard installation from the Legend (LGD) instructions. Federal Signal
recommends fusing each wired connection in Table 7 with the fuse shown in the
table. See Schematic A 7 on page 58.
Table 7 Model LPXD control wires for light activation
Wire Color
Red
Yellow
Blue
Gray
Brown
Brown/White
Orange
Green
Model LPXD Flash Pattern Compliances
The flash patterns listed as "Yes" (Y) in Table 7 comply with the SAE J845 flash
requirements and light output requirements. Patterns listed as "No" (N) do not
comply with these requirements. A non-compliant pattern should be used only
after the people you are trying to warn have been trained to recognize the pattern
as a warning signal. End users are responsible for choosing the flash patterns that
meet their jurisdiction's requirements.
Table 8 Model LPXD available flash patterns
Pattern
Number
P1
P2
P3
P4
P5
P6
P7
P8
16
Fuse
Light Activation
20 A
Front of light bar, Mode 1 (for rear cutoff, activate only the red wire)
20 A
Rear of light bar, Mode 1 (for front cutoff, activate only the yellow wire)
5 A
Mode 2: Overrides Mode 1
5 A
Flash takedown/alley
5 A
Left alley
5 A
Right alley
5 A
Worklight/takedown (If both options are installed, they work together.)
NA
Pattern change
Description
2 at 60 FPM QUAD FLASH Alternating, then
2 at 60 FPM DOUBLE FLASH Simultaneous
60 FPM 5-FLASH Alternating
60 FPM QUAD FLASH Alternating
75 FPM TRIPLE FLASH Alternating
85 FPM DOUBLE FLASH Alternating
115 FPM Alternating
152 FPM Alternating
1 at 60 FPM TRIPLE FLASH Alternating
2 at 60 FPM TRIPLE PULSE Simultaneous
***THIS FUNCTION IS GROUND ACTIVATED***
Legend LGD and Legend LPX Light Bars
Federal Signal www.fedsig.com
SAE J845
Compliant
N
Y
Y
Y
Y
Y
Y
N