6. Insert the 4 pin original wire harness plug
into the new controller.
8. We will be using an open hole on the
solenoid cover mounting tab to fasten the
walk-away relay and protection fuse.
10. Remove the pre-charge resistor and
connect the yellow wire from the walk-away
relay to the SOL- terminal and the red wire
from the fuse to the SOL terminal as shown.
62-EZHB-AO WORK INSTRUCTIONS REV. 02 9/14/2018
7. Remove the solenoid environmental
protection cover.
9. Using the supplied M5x20mm bolt,
washers, lock washer, and nut attach the
walk-away relay and fuse to the solenoid
cover mounting tab as shown.