7-5 Accumulation, Accumulation Display and Accumulation clear

Accumulation
Under the weighing mode, put the item on the weighing pan. Press key
"
appearance of
of the item.
Remove the item and the display goes back to zero before the next accumulation can register.
(The maximum is 99 pieces, display the latest 10 accumulation events in details )
Accumulation Display
MR/
Press key
to display the accumulation data
MR/
TARE/
or
The number of weighments is indicated by Auxiliary display at the left bottom.
XX=Total accumulation; XX=certain accumulation
Accumulation Clear
To clear accumulation data (total accumulation data or one of the accumulation events), press
M-/SET
key
while the data is displayed. To exit and return to normal weighing mode press key
ZERO/ESC.

8. Error message

Error Message
ERR0
ERR1
ERR2
ERR3
ERR4
ERR5
ERR6
ERR7
ERR8
ERR9
ERR10
". "
"
is displayed momentarily before the display reverts to the weight
to check the total accumulation and each accumulation event in detail.
Problem
Exceed the zero range
Model setting error. Resolution should be within 300-300000
Exceed the initial zero point
Exceed the A/D resolution range
EEPROM failure
Overload condition
Exceeds the display range
Accumulated number of weighments exceeds the display range
Lower limit is higher than upper limit
Exceed tare or pre-tare range
Wrong calibration weights