Troubleshooting; Replacement Parts/Accessories - Parkside PTPS 1100 A1 Translation Of The Original Instructions

Submersible dirty water pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
GB
IE

Troubleshooting

Faults
Pump does not start
Pumps has no dis-
charge
Pump does not switch
off
Flow rate insufficient
Pump switches off after
a short period

Replacement parts/Accessories

Spare parts and accessories can be obtained at
If you have issues ordering, please use the contact form.
If you have any other questions, contact the "Service-Center" (see page 27).
Item
8/9/10
11
28
Causes
Mains voltage is not applied
Float switch (
switch
Buckled pressure hose
Trapped air in the pump cas-
ing
Float switch (
drop
Reduces pump performance,
through severely contami-
nated water and additions in
the water which produce a
grinding effect
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Water temperature too high,
motor contactor breaks
www.grizzly-service.eu
Description
Connector set
8 m nylon cord
Remedies
Check mains voltage
Bring float switch into higher
3) does not
position
Repair point at which the line
is bent
Tip the pump underwater until
the air escapes
Set up pumps correctly on the
3) cannot
pit base
Clean pumps and replace
wear parts
Pull out power plug and clean
the pump as well as shaft
Note maximum water tem-
perature of 35 °C!
Product No.
91103475
91102503

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

316236 1904

Table of Contents