Step 7(e): No empty breaker
and two 200A sensors
Secure the
wire harness to the neutral bus bar. Turn off
a two-pole breaker and remove its wires.
Connect one of the breaker wires to the
Black
harness wire and an extra wire with a
wire nut. Next, connect the other breaker
wire to the
wire with a wire nut. Then secure the extra
wires to the two breaker poles. If you do not
have a two-pole breaker, you can use two
vertically adjacent single-pole breakers.
emporiaenergy.com/support
support@emporiaenergy.com
1-844-EMPORIA (367-6742)
White
and
Red
harness wire and an extra
Blue
wires from the
Need help?