Check Operation; Adjust Aeration (If Necessary); Install Handset Wall Holder - Valor G3 Classic Installation & Owner's Manual

Direct vent gas insert fireplace w/front and logs
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Check Operation

Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 8–9.

Adjust Aeration (if necessary)

Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutters are
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Air Shutters
Air Shutter
Slider & Cover
(natural gas)

Install Handset Wall Holder

The remote control kit for this fi replace
comes complete with a wall-mounted holder.
This holder is not required in all installations
but is provided as an optional feature for
those customers who wish to mount the
remote handset to the wall.
To install the holder to the wall, fi nd a
convenient location and use the hardware
provided with the kit. See the diagram below
for required hardware and confi gurations.
Note that the holder can be installed at the
base of a light switch plate.
IMPORTANT. The location of the remote
control handset is important to assure proper
temperature regulation. To obtain a constant temperature, we recommend that the handset should be between 3
and 15 feet away from the appliance but not directly above it. We also advise that the handset should be located
away from any other heat source and not in direct sunlight as this may aff ect the temperature sensor located in the
remote handset.
30
Installation
Natural gas
Close
Open
Close
Open
Packing Contents:
1 Wall Bracket A
2 Screws B
1 Screw C
2 Wall Anchor D
1 Spacer E
(detach before assembly)
1 Wall Bracket F
Depending of fuel bed used, altitude and other
considerations, the fl ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed and window installed and evaluating the fl ame
picture after a 15-minute warm-up.
Increasing aeration (open) will cause the fl ames
to appear more transparent and blue showing more
ceramic eff ects glow.
Decreasing aeration (close) will cause the fl ames to
appear more yellow or orange showing less ceramic
eff ects glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Flashback shield
(for propane gas
only)
Air Shutter Slider
(propane gas)
Alternative 2
Alternative 1
Propane gas
Close
Open
Alternative 3
Switch Plate

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

739-72jln739-72jlp

Table of Contents