Download Print this page

Preparation - Connection - LEGRAND DX3 Manual

Connected kit and automatic resetting manual supply invertor and accessories
Hide thumbs Also See for DX3:

Advertisement

STOP & GO automatic resetting
STOP & GO automatic resetting
STOP & GO automatic resetting
STOP & GO automatic resetting
4. 4. 4. 4. PREPARATION
PREPARATION
PREPARATION
PREPARATION - - - - CONNECTION
CONNECTION
CONNECTION
CONNECTION
Association:
Association:
Association:
Association:
. To be fitted to the left of MCB's DX
module per pole wide), RCCB's DX
(P+N et 2P
63A)
. No tool required. Clipped to the associated device by mean of
plastic clamps.
Wiring diagram:
Wiring diagram:
Wiring diagram:
Wiring diagram:
Protection of STOP&GO:
Protection of
STOP&GO:
Protection of
Protection of
STOP&GO:
STOP&GO:
. It is not necessary to install specific protections upstream of the
Stop & Go because it is self-protected
Connection:
Connection:
Connection:
Connection:
. Terminals protected against accidental contact (IP20, wired device).
Dep p p p th th th th of terminals
De
De
De
of terminals
of terminals : : : :
of terminals
. 10 mm.
Connectable section:
Connectable section:
Connectable section:
Connectable section:
Without ferrule
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
Rigid cable
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
Flexible cable
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
Technical data sheet: F01284EN/00
(continued):
10 000A (P+N, 1P, 2P - 1
3 3 3 3
2P and RCBO's DX
10 000A
3 3 3 3
3 3 3 3
Copper cables
With ferrule
- - - -
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
1 x 2,5mm²
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
2 x 1,5mm²
Updated: -
Cat. N°(s) : 4
Cat. N°(s)
: 4 062 88 / 89
062 88 / 89
Cat. N°(s)
Cat. N°(s)
: 4
: 4
062 88 / 89
062 88 / 89
4. 4. 4. 4. PREPARATION
PREPARATION
PREPARATION - - - - CONNECTION
PREPARATION
CONNECTION
CONNECTION
CONNECTION
Stripping length recommended:
Stripping length recommended:
Stripping length recommended:
Stripping length recommended:
. 7 mm.
Screw head:
Screw head:
Screw head:
Screw head:
. Slotted, diameter 3.5 mm.
Recommended tightening torque:
Recommended tightening torque:
Recommended tightening torque:
Recommended tightening torque:
. 0.4÷0.5 Nm.
Tools required:
Tools required:
Tools required:
Tools required:
. For the terminals: flat screwdriver 3.5 mm.
. For fixing: flat screwdriver 5.5 mm (6 mm maximum).
Lockout:
Lockout:
Lockout:
Lockout:
. By the sliding front face.
Sliding front face downward: the associated device goes into OFF
position and manual or automatic closing operations are disabled.
Sliding front face upward: the device is operating.
. Lockout by padlock Φ4mm only when the sliding front face is down.
Then mechanical and electrical controls are not possible.
Display of the device status and the status of the contacts s s s of of of of
Display of the device status and the status of the contact
Display of the device status and the status of the contact
Display of the device status and the status of the contact
the associated device:
the associated device:
the associated device:
the associated device:
. By handle mark:
"O-Off" white on a green background = device switched-off and
contacts opened.
"I-On" white on a red background = device powered-on and
contacts closed.
Device handle status: : : :
Device handle status
Device handle status
Device handle status
. The handle of the Stop & Go automatic resetting module, consists of
two parts:
- an "isolating" handle
- a "power" handle
. Operation sequences:
- Normal operation: both handle upward.
Created: 11/11/2011
(continued):
Isolating handle
Power handle
Isolating handle
Power handle
2/5

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Stop&go4 149 544 062 884 063 144 063 194062 89