Factory settings

Table 1
48
8. Commissioning
On start-up the meter uses the factory default setting in the SENSORPROM
following tables state the factory-set values. The range for each setting is given.
If a setting's range is exceeded, the cursor moves to the first character in the display and
flashes to indicate that the setting is invalid. The selected setting cannot be locked with
the LOCK key until a valid figure is selected. If the menu is left with cursor flashing, the
original value is maintained.
Since a number of factory-set values, e.g. max. volume flow, max. mass flow etc., are dimension-
dependent, these are given separately in the table "Dimension-dependent settings".
BASIC SETTINGS
Flow direction definition
Volume flow unit
Volume flow max.
Sound velocity, min.
Sound velocity, max.
Mass flow
Density unit
Sound Velocity 1
Density 1
Sound Velocity 2
Density 2
Mass flow unit
Mass flow max.
Totalizer 1
Totalizer 1 direction
Totalizer 1 unit
Totalizer 2
Totalizer 2 direction
Totalizer 2 unit
Low flow cut-off
Force control
OUTPUT SETUP
Current 1
Current 1 direction
Current 1 range
Current 1 Time constant
Current 2
Current 2 direction
Current 2 range
Current 2 Time constant
Current 3
Current 3 direction
Current 3 range
Current 3 Time constant
Frq.1/Pulse 1
Frq. 1/Pulse 1 direction
Frq. 1/Pulse 1
Pulse 1 unit
Pulse 1 Volume/pulse
Pulse 1 Width
Frq. 1 frequency
Frq. 1 time constant
SFIDK.PS.029.V3.02 - 521H0553
Factory settings
Settings available
Pos
Pos, Neg
m
3
/h
1300
1400
400 - 2000
1600
400 - 2000
Off
Scaled, O
kg/m
3
g/cm
3,
kg/m
1447
400 - 2000
997.7
1542
400 - 2000
998.0
ton/h
x x
1300
Off
Volume flow, Mass flow, Off
Pos
Pos, Neg, Bidirectional
m
3
Off
Volume flow, Mass flow, Off
Pos
Pos, Neg, Bidirectional
m
3
1.5%
0 - 9.9%
Off
Off, Max., Min.
Off
Volume flow, Mass flow, Sound Velocity, Off
Unidirectional
Unidirectional, Bidirectional
4 - 20 mA
0 - 20 mA, 4 - 20 mA
5 s
0.8 - 30 s
Off
Volume flow, Mass flow, Sound Velocity, Off
Unidirectional
Unidirectional, Bidirectional
4 - 20 mA
0 - 20 mA, 4 - 20 mA
5 s
0.8 - 30 s
Off
Volume flow, Mass flow, Sound Velocity, Off
Unidirectional
Unidirectional, Bidirectional
4 - 20 mA
0 - 20 mA, 4 - 20 mA
5 s
0.8 - 30 s
Off
Volume flow, Mass flow, Sound Velocity, Off
Unidirectional
Unidirectional, Bidirectional
Pulse
Frequency, Pulse
L, L × 10, L × 100, m
m
3
UG × 0.1, UG, UG × 10, UG × 100, MUG,
kg, kg × 10, kg × 100, ton, lb, lb × 10, lb × 100
1
50 µs, 500 µs, 50 ms E. Mech., 500 ms, 1 s, 5 s
50 ms
10 kHz
500 Hz, 1 kHz, 5 kHz, 10 kHz
5 s
0.8 - 30 s
®
memory unit. The
, N
, Ar, Off
2
2
3
, ton/m
3
, lb/ft
3
× 10, m
× 100,
3
, m
3
3

Hide quick links: