Installing the RTN 310
6
Installing the RTN 310 at an XPIC Site
CAUTION
1.
Cover unused ports with caps/PG covers. Retain removed caps for future use.
2.
Different methods can be used to change the polarization direction of antennas. If the method provided in this document is not suitable for the type of antennas you have, use the method provided in the installation manual
delivered with your antennas.
3.
If an antenna with a diameter of 0.6 m or less is used, you may install the RTN 310 and OMT on the antenna and then hoist them into position on the tower. For the installation method, see the installation guide delivered with
the OMT.
4.
Before installing a cable, bind the cable section that links the cable connector to the pole. This will protect the cable connector from damage. Be sure that the length of cable running from the binding point to the RTN 310 is
sufficient to attach the cable connector to the Ethernet service port on the RTN 310.
Installation procedure
1
Follow the antenna installation guide to
install the antenna.
2
Install the OMT by following instructions in
the OMT installation guide.
2
3
Apply petroleum jelly around the exterior
2
side of the feed.
Install the RTN 310 on the OMT.
4
NOTE
The RTN 310 can adapt to the polarization direction
of the antenna. No manual adjustment is required.
Install the PGND cable of the
5
RTN 310.
6
Install an XPIC cascade cable.
7
Install a GE cable.
• Install a GE cable.
• Select a ground point for the GE cable.
• Install a ground clip.
• Lay out the GE cable.
• Attach a yellow label to the cable
according to the plan.
8
Install a PI and cables on the PI.
• Install a PI on an auxiliary mounting bracket.
• Install the bracket in a 19-inch cabinet, ETSI
cabinet, or outdoor cabinet, or install the
bracket on a wall.
• Install cables on the PI.
Waterproof the ground clip.
9
Check the installation.
10
24/25 >>
1 to 4
COMBO
NOTE
• The P&E port can transmit/receive GE
(electrical) services.
• The RTN 310 provides power over Ethernet
through the P&E port.
GE
NMS
8
Connected to
Connected to the
the NMS
power supply
Transmits/Receives one
device
channel of FE/GE (electrical)
service.
P&E
COMBO
6
5
Grounded using a
ground clip
7
8
P&E
Site commissioning procedure
Power on the RTN 310.
1
Use a USB flash drive to load
2
NE data.
Use the Web LCT to configure
3
NE data.
P&E
Align antennas.
4
5
7