This command line instruct the modem to dial a remote modem through a PBX. The modem
first use pulse dialing to dial 9 (the access code of the PBX), wait for outside dial tone, and
then use touch tone dialing to dial 002 once a one-second continuous dial tone is detected
within 30 seconds, pause for 2 seconds (if S8=2) and then dial 8867128423.
5.3.2 Dialing a Stored Number
Command line: AT&Z2=T03,709394<CR>
Command line: ATDS=2<CR>
The first command line store the dial string T03, 709394 to the 3rd location in NVRAM. Afterwards
you can use the second command line to dial this stored number. The dial string T03, 709394 will
appear on the screen to indicate the number being dialed.
5.3.3 Manual Answer an Incoming Call
Command line: ATA <CR>
The factory setting of the S-register S0 is S0=0. This condition disables the auto answer capability so
that you must issue an ATA command to answer a call. At power up, your modem always monitors if
there are incoming rings. If incoming rings are detected, your modem will display result codes on the
screen as :
RING
:
:
RING
Seeing that, you may issue the ATA command to answer the call. This command must be entered
within the quiet interval between any two rings.
5.3.4 Auto Answer an Incoming Call
Command line: AT S0=2 &W &Y <CR>
Auto answer can be enabled by changing the setting of the S-register S0 to a value between 1 and 255.
In the above command line, S0=2 instructs the modem to answer an incoming call automatically after
the 2nd ring. The &W command writes this configuration to profile 0 in NVRAM. &Y command
instruct the modem to load profile 0 as the active configuration on power-up. The last two commands
make S0=2 the default value at power-up or reset.
This example also shows the insertion of space between two neighboring commands to make the
command line more readable.
5.3.5 Voice to Data Switch
Command line: ATA <CR> or ATX1D <CR>
If you are talking with a remote modem user through the telephone set and want to initiate data
communication with the remote modem, follow the procedures below:
1. You or the remote user issue an ATA command first to switch to data communication.