S3
Line Termination Character
S3 sets the decimal value of the command line and result code terminator character. Pertains
to asynchronous operation only.
Range:
S4
Response Formatting Character
S4 sets the decimal value of the character generated by the modem as part of the header,
trailer, and terminator for result codes and information text, along with the S3 parameter. If the
value of S4 is changed in a command line, the result codes issued in response to that
command line will use the new value of S4. The Response Formatting character is output
after the Line Termination character if verbose result codes are used.
Range:
S5
ASCII Value of Backspace Character
S5 stores the ASCII value of the backspace character. The backspace is used to edit a command line. If
your computer does not recognize the default as a backspace, change the value.
Range:
S6
Wait Time before Blind Dialing
S6 controls how long the modem waits after it goes off-hook before it dials the first digit of the
telephone number. The modem always pauses for at least 3 seconds, even if S6 is set to less than 3
seconds.
Range:
S7
Wait for Carrier after Dial
S7 controls how long the modem waits for a carrier signal from a remote modem after originating a call
or from the calling modem after going off-hook when answering a call.
S7 also controls how long the modem waits for a one-second continuous dialtone after dialing a
number followed by the W dial modifier. If the modem detects a one-second continuous dialtone
within the specified wait time, it proceeds to dial.
Range:
S8
Pause Time for Comma
S8 controls how long the modem pauses when a comma ", " is encountered in a dial string while
executing a dial command.
0 - 127, ASCII decimal.
0 - 127, ASCII decimal.
0 - 127, ASCII decimal.
3 - 7 seconds.
1 - 255 seconds.