Anchor Specifications

Static Anchor
KH-EZ 1/4"
HUS-H 6mm

Pullout Force

Life Fitness specifies Hilti
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided in
the side table. This table should be used for reference only; for additional and up-to-date information on the anchor
capabilities or the design pullout force in other substrates, please consult Hilti directly at https://www.us.hilti.com.
Selected Anchor
KH-EZ ¼" x 4"
HUS-H 6MM x 120MM
KH-EZ 3/8" x 4"
KH-EZ 3/8" x 5"
HUS-H 8MM x 120MM
HUS-H 8MM x 150MM
HSL-3 M 8/40
HST M12 x 115/20
HST M12 x 195/200
KB-TZ 3/8" x 3-3/4"
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.

Tools Required

WARNING: Adhere to manufacturer's equipment warnings and guidelines. Follow manufacturer's instructions
for proper usage.
Static Anchor
• Floor scanner / rebar detector (optional)
• 1" L-shape SDS rotary hammer
• 1/4" x 12" (6mm x 305mm) carbide drill bit (for 1/4"
(6mm) anchors)
• 3/8" x 12" (8mm x 305mm) carbide drill bit (for 3/8"
(8mm) anchors)

Static Anchor Procedure

CAUTION: If it is possible that the length of your bolt will not provide the minimum requirement of 2.5"
(63.5mm) of engagement, a longer anchor should be used.
1. Place unit into position to be mounted and cycle unit to set stance.
2. Each foot must get at least one static fastener.
Minimum Concrete
Minimum Drill Depth
Thickness
4-1/8" (105mm)
3-3/32" (100mm)
static and dynamic anchors. According to the anchor manufacturer, the recommended
Minimum Concrete
in Concrete
1/2" (12.7mm)
2-1/2" (63.5mm)
beyond anchor
length
25/64" (10mm)
2-1/64" (55mm)
beyond anchor
length
Design Resistance in Tension *
• Safety glasses
• Extension cord
• Impact wrench
• Vacuum (for debris)
Page 38 of 40
Minimum concrete
Embedment
compressive strength
3000psi (20 N/mm2)
3000psi (20 N/mm2)
830 lb
3.3 kN
1535 lb
1535 lb
3.3 kN
3.3 kN
2000 lb
8 kN
8 kN
1615 lb