5. Motor
1) Remove the registration roller (drive).
(Page 3-11)
2) Remove the gear
M2x2) and remove the motor
Figure 3-309
Notes on assembling
Insert the gear while rotating it slightly
because it is in the form of helix.
Insert the cable into its original position
and install the motor.
COPYRIGHT © CANON ELECTRONICS INC. 2012
1
and 2 screws
2
(PH
3
.
CANON P-208 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
6. Lower Reading Unit
1) Remove the entire upper unit.
(Page 3-3)
2) Remove the eject roller (drive).
(Page 3-11)
3) Remove the registration roller (drive).
(Page 3-11)
4) Remove the feed roller.
(Page 3-12)
5) Remove the motor.
(Page 3-13)
6) Remove the 2 gears
tion lever
2
and the document detection
lever
.
3
Figure 3-310
Note: The document detection lever is as-
sembled with a spring. An assembling
drawing is shown below.
Figure 3-311
, the open detec-
1
3-13